Intensity modulation under geometrical uncertainty: a deconvolution approach to robust fluence
Authors:
- Yankhua FanYFYankhua Fan
- Ravinder NathRNRavinder Nath
- 5 July 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (14) , 4029-4045
Abstract
A deconvolution algorithm has been developed to obtain robust fluence for external beam radiation treatment under geometrical uncertainties. Usually, the geometrical uncertainty is incorporated in the dose optimization process for inverse treatment planning to determine the additional intensity modulation of the beam to counter the geometrical uncertainty. Most of these approaches rely on dose convolution which is subject to the error caused by patient surface curvature and internal inhomogeneity. In this work, based on an 1D deconvolution algorithm developed by Ulmer and Kaissl, a fluence-deconvolution approach was developed to obtain robust fluence through the deconvolution of the nominal static one given by any treatment planning system. It incorporates the geometrical uncertainty outside the dose optimization procedure and therefore avoids the error of dose convolution. Robust fluences were calculated for a 4 x 4 cm flat field, a prostate IMRT and a head and neck IMRT plan in a commercial treatment planning system. The corresponding doses were simulated for 30 fractions with the random Gaussian distribution of the iso-centers showing good agreement with the nominal static doses. The feasibility of this deconvolution approach for clinical IMRT planning has been demonstrated. Because it is separated from the optimization procedure, this method is more flexible and easier to integrate into different existing treatment planning systems to obtain robust fluence.Keywords
This publication has 44 references indexed in Scilit:
- Robust Management of Motion Uncertainty in Intensity-Modulated Radiation TherapyOperations Research, 2008
- A robust approach to IMRT optimizationPhysics in Medicine & Biology, 2006
- Robust treatment planning for intensity modulated radiotherapy of prostate cancer based on coverage probabilitiesRadiotherapy and Oncology, 2006
- Robust optimization for intensity modulated radiation therapy treatment planning under uncertaintyPhysics in Medicine & Biology, 2005
- Treatment simulation approaches for the estimation of the distributions of treatment quality parameters generated by geometrical uncertaintiesPhysics in Medicine & Biology, 2004
- Adapting inverse planning to patient and organ geometrical variation: algorithm and implementationMedical Physics, 2003
- Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. I. The effect of shift invarianceMedical Physics, 2003
- A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up errorPhysics in Medicine & Biology, 2002
- Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulationPhysics in Medicine & Biology, 2002
- Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: a dosimetric studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999