Standardization of indoor radon measurements based on rational criterion for conformity assessment
Open Access
- 20 December 2023
- journal article
- research article
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (4) , 84-104
Abstract
Significant temporal variations in radon are observed in any buildings, including unoccupied buildings with limited ventilation. This fact causes serious difficulties in radiation monitoring to assess the compliance of premises with the requirements of the normative, which limits the annual average level of radon in buildings. Therefore, neither at the national nor at the international level has yet been solved the problem of standardizing the indoor radon measurement if the test duration is less than a year. An analysis of approaches to radon measurement, including an assessment of the effectiveness of regulation, shows very significant differences between practices established in different countries. For example, in Russia, rapid (no more than 20 min) measurements are mainly used and mitigation measures to protect existing buildings from radon are practically not carried out. In European countries, mainly long-term (at least two months) measurements are used, while mitigation measures are still relatively rare, with the exception of the UK and Sweden. In the USA, short-term (2–7 days) measurements are widely used, which are not only carried out, but also paid for by residents themselves, including mitigation measures. However, despite the established approaches to indoor radon monitoring in Russia and the USA, there is a persistent distrust among specialists in the results of shortterm and, especially, rapid measurements. In this regard, a compromise approach is proposed to standardize radon measurements based on a rational criterion by applying fundamental ISO/IEC concepts such as “measurement uncertainty” and “conformity assessment”. The rational criterion for conformity assessment allows using measurements of different durations, providing a given reliability when making a decision. It also proposes a rationale for optimizing indoor radon monitoring through the participation of not only professional inspectors, but also the population itself due to the possibility of introducing simple methods and inexpensive radon devices within the rational criterion.Keywords
This publication has 30 references indexed in Scilit:
- Air change rates and radon accumulation in rooms with various levels of window and door closureJournal of Building Physics, 2013
- Radon remediation and prevention status in 23 European countriesRadiation Protection Dosimetry, 2013
- Comparative analysis of radon, thoron and thoron progeny concentration measurementsJournal of Radiation Research, 2013
- Regional variation of seasonal correction factors for indoor radon levelsRadiation Measurements, 2011
- Correction factors for determination of annual average radon concentration in dwellings of Poland resulting from seasonal variability of indoor radonApplied Radiation and Isotopes, 2011
- On radon surveys: Design and data interpretationRadiation Measurements, 2009
- The value of Seasonal Correction Factors in assessing the health risk from domestic radon—A case study in Northamptonshire, UKEnvironment International, 2007
- Annual average and seasonal variations of residential radon concentration for all the Italian RegionsRadiation Measurements, 2005
- Seasonal changes in radon concentrations in buildings in the region of northeastern PolandJournal of Environmental Radioactivity, 2004
- Results of radon concentration measurements in some regions of RussiaRadiation Measurements, 1995