Evaluation of a commercial PET tomograph-based system for the quantitative assessment of rCBF, rOEF and rCMRO2 by using sequential administration of 15O-labeled compounds
- 1 July 2002
- journal article
- clinical trial
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 16 (5) , 317-327
Abstract
The purpose of this study was to develop a reliable and practical strategy that generates quantitative CBF and OEF maps accurately from PET data sets obtained with 15O-tracers. Sequential sinogram data sets were acquired after the administration of 15O-tracers, and combined single-frame images were obtained. The delay time between sampled input function and the brain was estimated from the H2 15O study with the whole brain and the arterial time-activity curves (TACs). The whole-brain TACs were obtained from the reconstructed images (image-base method) and the sinogram data (sinogram-base method). Six methods were also evaluated for the dead-time and decay correction procedures in the process of generating a single-frame image from the dynamic sinogram. The estimated delay values were similar with both the sinogram-based and image-based methods. A lumped correction factor to a previously added single-frame sinogram caused an underestimation of CBF, OEF and CMRO2 by 16% at maximum as compared with the correction procedure for a short sinogram. This suggested the need for a dynamic acquisition of a sinogram with a short interval. The proposed strategy provided an accurate quantification of CBF and OEF by PET with 15O-tracers.Keywords
This publication has 17 references indexed in Scilit:
- Quantitative Comparison of the Bolus and Steady-State Methods for Measurement of Cerebral Perfusion and Oxygen Metabolism: Positron Emission Tomography Study Using 15O-Gas and WaterJournal of Cerebral Blood Flow & Metabolism, 2001
- Optimization of Noninvasive Activation Studies with 15O-Water and Three-Dimensional Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1997
- Oxygen Consumption of the Living Human Brain Measured after a Single Inhalation of Positron Emitting OxygenJournal of Cerebral Blood Flow & Metabolism, 1992
- Evaluation of Regional Differences of Tracer Appearance Time in Cerebral Tissues Using [15O]Water and Dynamic Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1988
- A System for Cerebral Blood Flow Measurement Using an H215O Autoradiographic Method and Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1987
- Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input FunctionJournal of Cerebral Blood Flow & Metabolism, 1986
- Analysis of Some Errors in the Measurement of Oxygen Extraction and Oxygen Consumption by the Equilibrium Inhalation MethodJournal of Cerebral Blood Flow & Metabolism, 1985
- Radioactive oxygen-15 in the study of cerebral blood flow, blood volume, and oxygen metabolismSeminars in Nuclear Medicine, 1985
- A Statistical Study of the Steady State Technique for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using 15OJournal of Computer Assisted Tomography, 1982
- Error Analysis for the Determination of Cerebral Blood Flow with the Continuous Inhalation of 15O-Labeled Carbon Dioxide and Positron Emission TomographyJournal of Computer Assisted Tomography, 1982