Continuous Monitoring of Glucose in Subcutaneous Tissue Using Microfabricated Differential Affinity Sensors
Authors:
- Xian HuangXHXian Huang
- Bing SongBSBing Song
- Qiao LinQLQiao Lin
Open Access
- 1 November 2012
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 6 (6) , 1436-1444
Abstract
We describe miniaturized differential glucose sensors based on affinity binding between glucose and a synthetic polymer. The sensors possess excellent resistance to environmental disturbances and can potentially allow wireless measurements of glucose concentrations within interstitial fluid in subcutaneous tissue for long-term, stable continuous glucose monitoring (CGM). The sensors are constructed using microelectromechanical systems (MEMS) technology and exploit poly(N-hydroxy-ethyl acrylamide-ran-3-acrylamidophenylboronic acid) (PHEAA-ran-PAAPBA), a glucose-binding polymer with excellent specificity, reversibility, and stability. Two sensing approaches have been investigated, which respectively, use a pair of magnetically actuated diaphragms and perforated electrodes to differentially measure the glucose-binding-induced changes in the viscosity and permittivity of the PHEAA-ran-PAAPBA solution with respect to a reference, glucose-unresponsive polymer solution. In vivo characterization of the MEMS affinity sensors were performed by controlling blood glucose concentrations of laboratory mice by exogenous glucose and insulin administration. The sensors experienced an 8–30 min initialization period after implantation and then closely tracked commercial capillary glucose meter readings with time lags ranging from 0–15 min during rapid glucose concentration changes. Clarke error grid plots obtained from sensor calibration suggest that, for the viscometric and dielectric sensors, respectively, approximately 95% (in the hyperglycemic range) and 84% (ranging from hypoglycemic to hyperglycemic glucose concentrations) of measurement points were clinically accurate, while 5% and 16% of the points were clinically acceptable. The miniaturized MEMS sensors explore differential measurements of affinity glucose recognition. In vivo testing demonstrated excellent accuracy and stability, suggesting that the devices hold the potential to enable long-term and reliable CGM in clinical applications.Keywords
This publication has 33 references indexed in Scilit:
- Glucose Biosensors: An Overview of Use in Clinical PracticeSensors, 2010
- A novel competitive capacitive glucose biosensor based on concanavalin A-labeled nanogold colloids assembled on a polytyramine-modified gold electrodeAnalytica Chimica Acta, 2010
- A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymerSensors and Actuators B: Chemical, 2009
- A Tale of Two Compartments: Interstitial Versus Blood Glucose MonitoringDiabetes Technology & Therapeutics, 2009
- A MEMS viscometric sensor for continuous glucose monitoringJournal of Micromechanics and Microengineering, 2007
- Engineering and rapid selection of a low-affinity glucose/galactose-binding protein for a glucose biosensorProtein Science, 2007
- Glucose recovery in a microfluidic microdialysis biochipSensors and Actuators B: Chemical, 2005
- A novel glucose sensor system with Au nanoparticles based on microdialysis and coenzymes for continuous glucose monitoringSensors and Actuators A: Physical, 2003
- Calibration of a subcutaneous amperometric glucose sensorBiosensors and Bioelectronics, 2002
- Polyacrylamide solutions for DNA sequencing by capillary electrophoresis: Mesh sizes, separation and dispersionElectrophoresis, 1996