Internal movement, set-up accuracy and margins for stereotactic body radiotherapy using a stereotactic body frame
Authors:
- Anders T. HansenAHAnders T. Hansen
- Jørgen B. PetersenJPJørgen B. Petersen
- Morten HøyerMHMorten Høyer
- 1 January 2006
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 45 (7) , 948-952
Abstract
The aim of this study was to evaluate the uncertainty of patient immobilization within the Elekta body frame (SBF) used for stereotactic body radiotherapy (SBRT) and to suggest margins sufficient to ensure dose coverage to the gross target volume (GTV). The study was based on the evaluation of repeated CT-scans of 30 patients treated by SBRT. The overall uncertainty was divided between uncertainty related to internal movement of the tumor and uncertainty in the patient set-up. Standard deviations of the overall tumor displacement were 2 mm, 3 mm and 4 mm in medial-lateral (m-l), anterior-posterior (a-p), and cranio-caudal (c-c) directions, respectively. In a model based on the data, an ellipsoid planned target volume (PTV) corresponding to the standard deviations in the orthogonal directions and a scaling factor, K defined a 3-dimentional (3-D) probability density. According to the model, a 90% probability of full dose coverage of the GTV was secured using margins of 9 mm (m-l), 9 mm (a-p) and 13 mm (c-c), respectively. The overall uncertainty was dominated by internal tumor movements whereas the set-up uncertainty of the patient in the SBF was less pronounced. It was concluded that the Elekta SBF is useful for immobilisation of patients for SBRT. However, due to internal movement conventional margins of 5 mm in m-l and a-p and 10 mm in the c-c directions may be insufficient for full dose coverage.Keywords
This publication has 14 references indexed in Scilit:
- Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Prospective Study on Stereotactic Radiotherapy of Limited Stage Non-Small Cell Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liverRadiotherapy and Oncology, 2003
- Stereotactic single high dose irradiation of lung tumors under respiratory gatingRadiotherapy and Oncology, 2002
- Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frameRadiotherapy and Oncology, 2000
- The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000
- Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000
- Extracranial Stereotactic Radiosurgery of Localized TargetsJournal of Radiosurgery, 1998
- Stereotactic High Dose Fraction Radiation Therapy of Extracranial Tumors Using An Accelerator: Clinical experience of the first thirty-one patientsActa Oncologica, 1995
- Stereotactic Radiotherapy of Malignancies in the Abdomen: Methodological aspectsActa Oncologica, 1994