Dynamic gamma knife radiosurgery
Authors:
- Shuang LuanSLShuang Luan
- Nathan SwansonNSNathan Swanson
- Zhe ChenZCZhe Chen
- Lijun MaLMLijun Ma
- 19 February 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (6) , 1579-1591
Abstract
Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a ‘ball-packing’ approach and delivered in a ‘step-and-shoot’ manner, i.e. it aims to ‘pack’ the different sized spherical high-dose volumes (called ‘shots’) into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of ‘dose-painting’ to take advantage of the new robotic patient positioning system on the latest Gamma Knife C™ and Perfexion™ units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical ‘paintbrush’, and treatment planning reduces to finding the best route of this ‘paintbrush’ to ‘paint’ a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and the dose distributions, thus giving the clinician one more dimension of flexibility of choosing a plan based on the clinical situations.Keywords
This publication has 25 references indexed in Scilit:
- Gamma knife for glioma: Selection factors and survivalInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Proton magnetic resonance spectroscopy in patients with glial tumors: a multicenter studyJournal of Neurosurgery, 1996
- Irradiation Effects on the Metabolism of Metastatic Brain Tumors: Analysis by Positron Emission Tomography and 1H-Magnetic Resonance SpectroscopyStereotactic and Functional Neurosurgery, 1996
- Advances in brain tumor diagnostic imagingCurrent Opinion in Neurology, 1995
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1994
- An analytical solution for the dynamic control of multileaf collimatorsPhysics in Medicine & Biology, 1994
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992
- Characterization of astrocytomas, meningiomas, and pituitary adenomas by phosphorus magnetic resonance spectroscopyJournal of Neurosurgery, 1991
- Approximation schemes for covering and packing problems in image processing and VLSIJournal of the ACM, 1985
- Solution of an integral equation encountered in rotation therapyPhysics in Medicine & Biology, 1982