Comparison of Continuous Noninvasive Blood Pressure Monitoring by TL-300 With Standard Invasive Blood Pressure Measurement in Patients Undergoing Elective Neurosurgery
Authors:
Open Access
- 1 January 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Neurosurgical Anesthesiology
- Vol. 29 (1) , 1-7
Abstract
Background: Intraoperative blood pressure (BP) is one of the basic vital signs monitoring. Compared with standard invasive BP measurement, TL-300 allows for a continuous and beat-to-beat noninvasive intraoperative BP monitoring. The current retrospective study compared the accuracy and precision of this noninvasive technique for continuous BP monitoring with that of standard invasive BP measurement in patients undergoing elective neurosurgery. Materials and Methods: BP records of 23 patients undergoing elective neurosurgery, measured by both noninvasive TL-300 and invasive radial arterial catheter method, were retrospectively analyzed. Variability in BP data was analyzed by using linear regressions and Bland-Altman analysis. Results: Four thousand three hundred eighty-one pairs of BP measurements from a total of 23 patients were included. The coefficient of determination of systolic, diastolic, and mean BP were 0.908, 0.803, and 0.922, respectively. And their bias was found to be 1.3±5.87 mm Hg (95% limits of agreement: −10.2 to +12.8 mm Hg), 2.8±6.40 mm Hg (95% limits of agreement: −9.8 to +15.3 mm Hg), and 1.8±4.20 mm Hg (95% limits of agreement: −6.4 to +10.1 mm Hg), respectively. Conclusions: TL-300 system is a promising noninvasive alternative to the invasive arterial catheter method for intraoperative BP monitoring, with a high accuracy and precision. With the limitation of the current retrospective study, further prospective method comparison studies are needed.Keywords
This publication has 24 references indexed in Scilit:
- Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometryJournal of Clinical Monitoring and Computing, 2012
- Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologistsCritical Care, 2011
- Clinical review: Update on hemodynamic monitoring - a consensus of 16Critical Care, 2011
- Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic InvestigationsAnesthesia & Analgesia, 2009
- Can Femoral Artery Pressure Monitoring Be Used Routinely in Cardiac Surgery?Journal of Cardiothoracic and Vascular Anesthesia, 2008
- An evaluation of the T‐Line ® Tensymeter continuous noninvasive blood pressure device during induced hypotension*Anaesthesia, 2008
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Oscillometric brachial mean artery pressures are higher than intra‐radial mean artery pressures in intensive care unit patients receiving norepinephrineActa Anaesthesiologica Scandinavica, 2006
- An Accuracy Evaluation of the T-Line® Tensymeter (Continuous Noninvasive Blood Pressure Management Device) versus Conventional Invasive Radial Artery Monitoring in Surgical PatientsAnesthesia & Analgesia, 2006
- Short report: An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devicesJournal Of Hypertension, 1993