Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty
- 1 November 2005
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 87-B (11) , 1493-1497
Abstract
Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.Keywords
This publication has 23 references indexed in Scilit:
- A novel method for in vivo knee prosthesis wear measurementJournal of Biomechanics, 2005
- In vivo measurement of total knee replacement wearThe Knee, 2004
- Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysisThe Knee, 2004
- Accurate in vivo measurement of polyethylene wear in total knee arthroplastyThe Journal of Arthroplasty, 2002
- Wear of congruent meniscal bearings in unicompartmental knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1998
- The Oxford medial unicompartmental arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1998
- Study of creep behavior of ultra-high-molecular-weight polyethylene systemsJournal of Biomedical Materials Research, 1998
- Theory and Practice of Meniscal Knee Replacement: Designing against WearProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1996
- Multicenter study of unicompartmental knee revisionActa Orthopaedica, 1992
- Polyethylene wear in knee arthroplastyActa Orthopaedica, 1992