Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in stroke
Open Access
- 5 April 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (5) , 1180-1185
Abstract
Perfusion maps, which are calculated from dynamic‐susceptibility contrast (DSC)‐MRI data by deconvolution of the arterial input function (AIF), are commonly used to predict tissue infarction in acute stroke. However, since the AIF is commonly measured in a major artery, there can be perfusion measurement errors associated with bolus delay/dispersion. Although methods to account for delay‐related errors have been proposed, the effect of dispersion is more difficult to deal with and is usually left uncorrected. This study presents an assessment of the delay–dispersion relationship in a group of patients. Although a significant correlation was observed with one of the bolus delay definitions used, the estimation of the dispersion from the degree of delay was unreliable. Importantly, the dispersion observed in many patients was sufficient to result in substantial perfusion errors. The results are compared with previous numerical simulations, and their implications for the assessment and management of acute stroke are discussed. Magn Reson Med, 2006.Keywords
This publication has 22 references indexed in Scilit:
- Bolus dispersion issues related to the quantification of perfusion MRI dataJournal of Magnetic Resonance Imaging, 2005
- Tracer Delay Correction of Cerebral Blood Flow with Dynamic Susceptibility Contrast-Enhanced MRIJournal of Cerebral Blood Flow & Metabolism, 2005
- Magnetic Resonance Imaging Criteria for Thrombolysis in Acute Cerebral InfarctStroke, 2005
- Perfusion assessment with bolus differentiation: A technique applicable to hyperpolarized tracersMagnetic Resonance in Medicine, 2004
- Defining a local arterial input function for perfusion MRI using independent component analysisMagnetic Resonance in Medicine, 2004
- Tracer arrival timing‐insensitive technique for estimating flow in MR perfusion‐weighted imaging using singular value decomposition with a block‐circulant deconvolution matrixMagnetic Resonance in Medicine, 2003
- Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in StrokeStroke, 2002
- Modeling Cerebral Blood Flow and Flow Heterogeneity from Magnetic Resonance Residue DataJournal of Cerebral Blood Flow & Metabolism, 1999
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H215O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input FunctionJournal of Cerebral Blood Flow & Metabolism, 1986