Refractive indices for volatile anesthetic gases: Equipment and method for calibrating vaporizers and monitors
Authors:
- 1 May 1995
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 11 (3) , 168-174
Abstract
Objective. The objective of our study was to establish the refractive indices and the virial coefficients of the volatile anesthetic vapors. These indices and coefficients will allow refractometry to be used by manufacturers to produce accurate calibration, without requiring expensive high-precision calibration gases.Methods. We used a precision refractometer to measure the refractive indices for five volatile anesthetic vapors. We prepared our calibration gases by mixing a gravimetrically calibrated amount of liquid agent with a constant gas flow.Results. The refractive indices for the volatile anesthetic vapors are 1,603.2 for halothane, 1,540.4 for enflurane, 1,563.3 for isoflurance, 1,538.3 for sevoflurane, and 1,211.7 for desflurane. The maximum theoretical error in our measurements, due to all sensors and all uncertainty in our measurement of apparatus and physical constants, is ±0.56% of the reading (±0.70% for desflurane).Conclusions. If refractometry replaced calibration gases in cylinders, as a calibration standard, manufacturers might avoid errors that now occur because calibration gases manufactured by numerous companies seem to differ. We propose that our values serve as an interim database.Keywords
This publication has 21 references indexed in Scilit:
- Measurements of the second virial coefficients of some new chlorofluorocarbons and of their mixtures at temperatures in the range from 230 K to 300 KThe Journal of Chemical Thermodynamics, 1991
- Technical Realisation of Quantitative Metering and Ventilation1989
- Bi-directional fringe counting interference refractometerPrecision Engineering, 1983
- Do Volatile Anesthetics Act as Ideal Gases?Anesthesia & Analgesia, 1979
- Automatic Interferometer with Digital Readout for Refractometric AnalysisApplied Optics, 1968
- Vapour pressure and vapour density of halothane (2-bromo-2-chloro-1,1,1-trifluoroethane)Journal of Chemical Technology & Biotechnology, 1963
- Fractional-Fringe Measurements with the Corner-Cube InterferometerJournal of the Optical Society of America, 1955
- Wavelength or Length Measurement by Reversible Fringe Counting*Journal of the Optical Society of America, 1953
- A New Principle in Interferometer DesignJournal of the Optical Society of America, 1948
- IV. On some physical properties of argon and heliumProceedings of the Royal Society of London, 1896