Power losses analysis of two-level and three-level neutral clamped inverters for a wind pump storage system
Authors:
- 1 May 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 18420133,p. 1174-1179
Abstract
The purpose of the paper is analyzing the possibilities of improving the efficiency of a 2 kW wind pump storage system at low wind conditions. Two possible solutions are considered for the converter supplying the induction motor pump system: two-level and respectively three-level NPC inverter. Inverter total power losses are computed based on models proposed in the paper, considering a very low wind speed. Space vector pulse width modulation technique is used in both cases. Trench IGBT modules of 1200 V, respectively 600 V are considered as switches and 600 V SIC diode as clamping diode for the three-level NPC inverter.Keywords
This publication has 7 references indexed in Scilit:
- Simulink model of flying capacitor multilevel inverter2008
- On the Efficiency of Voltage Source and Current Source Inverters for High-Power DrivesIEEE Transactions on Industrial Electronics, 2008
- A new stacked NPC converter: 3L-topology and control2007
- Application of Three-level Converters to Wind Power Systems with Permanent-magnet Synchronous Generators2007
- High‐Power Converters and ac Drives2005
- Multilevel inverters: a survey of topologies, controls, and applicationsIEEE Transactions on Industrial Electronics, 2002
- Power losses in PWM-VSI inverter using NPT or PT IGBT devicesIEEE Transactions on Power Electronics, 1995