Prediction of leakage current in transformerless photovoltaic inverter system by a more accurate method
Authors:
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 3314-3318
Abstract
In case of the grid connected transformerless photovoltaic (PV) inverter, the leakage current through the parasitic capacitance of the PV panel can cause very serious electromagnetic interference problems. In this paper, a more accurate high frequency PV array model is proposed. It includes the influence of PV frame, mounting rack, solar cell material and area. Based upon that model, the common mode leakage current is predicted through numerical analysis and calculation. The accuracy of the theoretical results is certified by MATLAB simulation and experimental test. This developed method can be easily incorporated into PV inverter system for further device/circuit design optimization with various panel parameters.Keywords
This publication has 3 references indexed in Scilit:
- Evaluation of Three-Phase Transformerless Photovoltaic Inverter TopologiesIEEE Transactions on Power Electronics, 2009
- Common mode voltage in case of transformerless PV inverters connected to the grid2008
- Transformerless Inverter for Single-Phase Photovoltaic SystemsIEEE Transactions on Power Electronics, 2007