Observations of Femoral Rollback in Cruciate-Retaining Knee Arthroplasty
Authors:
- Hiroyuki NozakiHNHiroyuki Nozaki
- Scott A. BanksSBScott A. Banks
- Tohru SuguroTSTohru Suguro
- W. Andrew HodgeWHW. Andrew Hodge
- 1 November 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 404 (404) , 308-314
Abstract
The current study evaluated kinematics of the knee during a stair-climbing activity after total knee arthroplasty. All patients received a posterior cruciate ligament retaining prosthesis of the same design, having an anatomically shaped femoral component and an unconstrained tibial insert. All patients had the same surgical technique done by two experienced surgeons. Patients had some posterior femoral rollback and screw-home type axial rotations during weightbearing activities. However, patients treated by different surgeons had different patterns of tibiofemoral motions. In Group 1, rollback occurred early in the flexion range and was maintained until 80° flexion. In Group 2, the lateral condyle had rollback in early flexion, but both condyles translated forward as flexion increased to 80°. An anatomic femoral component seems to be necessary to produce consistent early femoral rollback. However, soft tissue balance can have a significant effect on the kinematics of sagittally unconstrained posterior cruciate retaining total knee arthroplasty, because it may vary among surgeons.Keywords
This publication has 19 references indexed in Scilit:
- A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplastyThe Journal of Arthroplasty, 2000
- Three-dimensional knee kinematics and stability in patients with a posterior cruciate ligament tearJournal of Orthopaedic Research, 1999
- Rollback in posterior cruciate ligament—retaining total knee arthroplastyThe Journal of Arthroplasty, 1997
- In vivo kinematics of cruciate-retaining and -substituting knee arthroplastiesThe Journal of Arthroplasty, 1997
- In Vivo Knee Kinematics Derived Using an Inverse Perspective TechniqueClinical Orthopaedics and Related Research, 1996
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Posterior cruciate function following total knee arthroplastyThe Journal of Arthroplasty, 1994
- Three‐dimensional knee joint movements during a step‐up: Evaluation after anterior cruciate ligament ruptureJournal of Orthopaedic Research, 1994
- The effect of preoperative knee deformity on the initial results of cruciate-retaining total knee arthroplastyThe Journal of Arthroplasty, 1992
- Interaction between intrinsic knee mechanics and the knee extensor mechanismJournal of Orthopaedic Research, 1987