Spectrophotometric determination of turbid optical parameters without using an integrating sphere.
Authors:
- 10 March 2016
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (8) , 2079-2085
Abstract
Spectrophotometric quantification of turbidity by multiple optical parameters has wide-ranging applications in material analysis and life sciences. A robust system design needs to combine hardware for precise measurement of light signals with software to accurately model measurement configuration and rapidly solve a sequence of challenging inverse problems. We have developed and validated a design approach and performed system validation based on radiative transfer theory for determination of absorption coefficient, scattering coefficient, and anisotropy factor without using an integrating sphere. Accurate and rapid determination of parameters and spectra is achieved for microsphere suspension samples by combining photodiode-based measurement of four signals with the Monte Carlo simulation and perturbation-based inverse calculations. The three parameters of microsphere suspension samples have been determined from the measured signals as functions of wavelength from 400 to 800 nm and agree with calculated results based on the Mie theory. It has been shown that the inverse problems in the cases of microsphere suspension samples are well posed with convex cost functions to yield unique solutions, and it takes about 1 min to obtain the three parameters per wavelength.Keywords
This publication has 26 references indexed in Scilit:
- Flexible tool for simulating the bulk optical properties of polydisperse spherical particles in an absorbing host: experimental validationOptics Express, 2014
- Supercontinuum laser based optical characterization of Intralipid® phantoms in the 500-2250 nm rangeOptics Express, 2013
- Fast method for inverse determination of optical parameters from two measured signalsOptics Letters, 2013
- Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2000 nmJournal of Biomedical Optics, 2009
- Effect of surface roughness on determination of bulk tissue optical parametersOptics Letters, 2003
- Optical tomography using the time-independent equation of radiative transfer — Part 1: forward modelJournal of Quantitative Spectroscopy and Radiative Transfer, 2002
- Determining the optical properties of turbid media by using the adding–doubling methodApplied Optics, 1993
- Optical properties of normal and diseased human breast tissues in the visible and near infraredPhysics in Medicine & Biology, 1990
- Spectrophotometry of Clarified Cell SuspensionsScience, 1955
- CLINICAL STUDIES OF THE BLOOD VOLUME. I. CLINICAL APPLICATION OF A METHOD EMPLOYING THE AZO DYE “EVANS BLUE” AND THE SPECTROPHOTOMETERJournal of Clinical Investigation, 1937