Fatal Intoxication Involving 3-MeO-PCP: A Case Report and Validated Method
Authors:
Open Access
- 23 June 2016
- journal article
- case report
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 40 (7) , 504-510
Abstract
We present in this case report a validated method for accurate quantitative analysis of 3-methoxy phencyclidine (3-MeO-PCP) to determine postmortem blood concentrations of this PCP analog. A 29-year-old male with a history of illicit drug use was found unresponsive in his bed with a bag of white powder next to him. Resuscitation efforts were unsuccessful and the individual was pronounced dead 9 minutes after arrival to the hospital. Initial ELISA screening suggested the presence of PCP in the decedent's blood. However, confirmatory testing revealed no detectable PCP. Instead, a large peak corresponding to a m/z 274.218 species with retention time similar to PCP was present on a LC-TOF-MS drug screen, suggesting a possible PCP analog. This mass corresponds specifically to a methoxy-PCP analog, several of which are available for purchase online. Standards for 3-MeO-PCP and 4-MeO-PCP were obtained and injected on the same instrument. Although the 3- and 4-MeO-PCP analogs have identical masses and retention times, they are still distinguishable through their mass spectra. The peak from the decedent's sample matched both the mass spectrum and the retention time of 3-MeO-PCP. A quantitative LC–MS-MS method was subsequently developed and validated for casework. Analysis using this method revealed a concentration of 139 ± 41 µg/L 3-MeO-PCP in the decedent's blood. Diphenhydramine (4.1 ± 0.7 mg/L), marijuana metabolite (presumptive positive, confirmation not performed) and a small amount of amphetamine (<0.10 mg/L) were also found in the decedent's blood. The cause of death was determined to be combined 3-MeO-PCP, diphenhydramine and amphetamine toxicity. The manner of death was certified as an accident.Keywords
Funding Information
- Harris County Institute of Forensic Sciences
This publication has 19 references indexed in Scilit:
- How often do false-positive phencyclidine urine screens occur with use of common medications?Clinical Toxicology, 2013
- From the Street to the Laboratory: Analytical Profiles of Methoxetamine, 3-Methoxyeticyclidine and 3-Methoxyphencyclidine and their Determination in Three Biological MatricesJournal of Analytical Toxicology, 2013
- Preparation and analytical characterization of 1‐(1‐phenylcyclohexyl)piperidine (PCP) and 1‐(1‐phenylcyclohexyl)pyrrolidine (PCPy) analoguesDrug Testing and Analysis, 2013
- The Ketamine Analogue Methoxetamine and 3- and 4-Methoxy Analogues of Phencyclidine Are High Affinity and Selective Ligands for the Glutamate NMDA ReceptorPLOS ONE, 2013
- Validation of LC–TOF-MS Screening for Drugs, Metabolites, and Collateral Compounds in Forensic Toxicology SpecimensJournal of Analytical Toxicology, 2012
- Phenomenon of new drugs on the Internet: the case of ketamine derivative methoxetamineHuman Psychopharmacology: Clinical and Experimental, 2012
- Clinical toxicology of newer recreational drugsClinical Toxicology, 2011
- Phencyclidine: A 5-Year Retrospective Review from the New York City Medical Examiner’s OfficeJournal of Forensic Sciences, 2011
- PCP: from pharmacology to modelling schizophreniaCurrent Opinion in Pharmacology, 2005
- A 5-Year Stability Study of Common Illicit Drugs in BloodJournal of Analytical Toxicology, 1995