A comparative SEM study between hand instrument and Er:YAG laser scaling and root planing
- 18 November 2006
- journal article
- research article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 22 (1) , 25-29
Abstract
Scaling and root planing are one of the most commonly used procedures for the treatment of periodontal diseases. Removal of calculus using conventional hand instruments is incomplete and rather time-consuming. In search for more efficient and less difficult instrumentation, investigators have proposed lasers as alternatives or adjuncts for scaling and root planing. The aim of the present study was to compare the effectiveness of subgingival scaling and root planing with erbium: yttrium, aluminium, garnet (Er:YAG) laser and hand instrumentation in vitro. The mesial and distal surfaces of 15 periodontal loosed extracted teeth were treated randomly either by hand instrumentation or by Er:YAG laser irradiation. After choosing the “very long pulse mode” (pulse duration of about 700 μs), the output energy of 160 mJ with 920-μm beam diameter (RO7 Perio tip, Fidelis, Fotona, Slovenia) and frequency of 12 Hz were selected, both according to the best results of past studies. In addition, air water spray was used during the procedures. The morphology of the root surface was evaluated by three observers with a scanning electron microscopy in magnifications of 50× and 400×. The result of this setting showed that the rate of remained roughness on treated root surfaces in two groups of hand instruments and Er:YAG laser had a meaningful difference: The surface roughness in Er:YAG laser group was more than in hand instruments group. The present study could demonstrate the in vitro capability of the Er:YAG laser for scaling and root planing in periodontitis, although the effectiveness of this setting did not reach that achieved by hand instrumentation. It could be concluded that lower frequency and long pulse duration maybe more suitable for the micro-morphology of root surface after treatment. This theory is going to be tested with the same laser instrument in the next study.Keywords
This publication has 24 references indexed in Scilit:
- Potential applications of Erbium:YAG laser in periodonticsJournal of Periodontal Research, 2004
- Adhesion and Growth of Cultured Human Gingival Fibroblasts on Periodontally Involved Root Surfaces Treated by Er:YAG LaserJournal of Periodontology, 2003
- Influence of the spatial beam profile on hard tissue ablation Part I: Multimode emitting Er:YAG lasersLasers in Medical Science, 2003
- Influence of the Pulse Duration of an Er:YAG Laser System on the Ablation Threshold of Dental EnamelLasers in Medical Science, 2002
- Morphological analysis of cementum and root dentin after Er:YAG laser irradiationLasers in Surgery and Medicine, 2002
- Treatment of Plaque‐Induced Gingivitis, Chronic Periodontitis, and Other Clinical ConditionsJournal of Periodontology, 2001
- Morphology, chemical structure and diffusion processes of root surface after Er:YAG and Nd:YAG laser irradiationJournal of Clinical Periodontology, 2001
- The effects of C02, Nd: YAG and Er: YAG lasers with and without surface coolant on tooth root surfacesJournal of Clinical Periodontology, 1997
- Effect of nonsurgical periodontal therapyJournal of Clinical Periodontology, 1984
- Root Planing: A PerspectiveJournal of Periodontology, 1977