Effect of intermittent loading and surface roughness on peri‐implant bone formation in a bone chamber model
- 11 October 2007
- journal article
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 34 (11) , 998-1006
Abstract
Both implant surface characteristics and mechanical loading are known to affect implant osseointegration. Their interaction and the underlying mechanisms by which they affect peri‐implant healing processes are still unknown. The aim of this study is therefore to investigate the influence of a turned versus a rough (Plus®, Dentsply Friadent) implant surface on peri‐implant bone formation in case of unloaded or loaded implant healing.Material and Methods: Bone formation was evaluated around screw‐shaped implants under four experimental conditions using a repeated sampling bone chamber methodology: (1) unloaded turned implant (CU), (2) unloaded implant with a rough surface (TU), (3) loaded turned implant (CL), and (4) loaded implant with a rough surface (TL). Peri‐implant tissue samples were paraffin embedded after implant removal and examined histologically and histomorphometrically. A mixed model was used for statistical analysis.Results: The surface of bone tissue relative to the total tissue area (bone area fraction) was not affected by the experimental conditions. The areas of bone trabeculae relative to the bone area (bone fraction) were significantly higher for TL compared with CU and TU. The bone fraction in the vicinity (100 μm zone) of the implant (BFZ) was significantly the highest around the loaded roughened implants (TL).Conclusion: Implant loading did not affect bone formation in the absence of surface roughness, and implant surface roughness had no effect in the absence of loading. However, a bone‐stimulating effect in the implant's vicinity was assigned to the rough surface when the implant was loaded.Keywords
This publication has 28 references indexed in Scilit:
- Histodynamics of bone tissue formation around immediately loaded cylindrical implants in the rabbitClinical Oral Implants Research, 2007
- Effect of mechanical stimuli on skeletal regeneration around implantsBone, 2007
- Influence of controlled immediate loading and implant design on peri‐implant bone formationJournal of Clinical Periodontology, 2006
- Bone regeneration at implants with turned or rough surfaces in self‐contained defects. An experimental study in the dogJournal of Clinical Periodontology, 2005
- Expression of Runx2/Cbfa1/Pebp2αA During Angiogenesis in Postnatal Rodent and Fetal Human Orofacial TissuesJournal of Bone and Mineral Research, 2005
- A repeated sampling bone chamber methodology for the evaluation of tissue differentiation and bone adaptation around titanium implants under controlled mechanical conditionsJournal of Biomechanics, 2004
- Early bone formation adjacent to rough and turned endosseous implant surfacesClinical Oral Implants Research, 2004
- Transcription and immunolocalization of Runx2/Cbfa1/Pebp2αA in developing rodent and human craniofacial tissues: Further evidence suggesting osteoclasts phagocytose osteocytesMicroscopy Research and Technique, 2003
- Implant‐retained mandibular overdentures with ITI implantsClinical Oral Implants Research, 2002
- A histomorghometric study of screw‐shaped and removal torque titanium implants with three different surface topographiesClinical Oral Implants Research, 1995