Finite Element Analysis (FEA) for the Evaluation of Retention in a Conometric Connection for Implant and Prosthesis
Open Access
- 4 December 2023
- Vol. 3 (4) , 140-156
Abstract
Today, dental implantology represents a reliable technique for treating both partial and total edentulism. The fixation of dentures on dental implants can be achieved using various techniques, where the choice of a specific technique depends on the patient’s individual needs, the jawbone’s condition, and the prosthesis design. Currently, the two most common types of prosthetic abutment connections are cemented and screwed, each with its own set of advantages and disadvantages. This study aimed to analyze a novel Morse cone connection system between the prosthesis and implant using finite element analysis (FEA). The analysis of connection retention was conducted using three different approaches: analytical, in vitro, and FEA. Three-dimensional models were created for systems comprising an abutment, healing cap, and crown under three inclination conditions: 0°, 15°, and 30°. Using Ansys finite element software (R1 2023), the impact of the tilt on the system retention was examined. The FEA showed results comparable with the in vitro studies regarding the retention strength for an abutment cap system with a 4° taper, obtaining 66.6 N compared with the 68 N calculated in our in vitro study. The inclination of the abutment affected the system retention due to the hole made in the abutment’s surface, decreasing the contact area between components. The Morse cone prosthesis–implant connection system was found to be the most stable and efficient compared with threaded or cemented systems. The retention was influenced by factors such as the abutment conicity, insertion strength, and the contact surface between components.Keywords
All Related Versions
This publication has 56 references indexed in Scilit:
- Survival and Complication Rates of Fixed Restorations Supported by Locking‐Taper Implants: A Prospective Study with 1 to 10 Years of Follow‐UpJournal of Prosthodontics, 2014
- Erratum to “Comparative Evaluation of Osseointegrated Dental Implants Based on Platform-Switching Concept: Influence of Diameter, Length, Thread Shape, and In-Bone Positioning Depth on Stress-Based Performance”Computational and Mathematical Methods in Medicine, 2014
- Conometric retention for complete fixed prosthesis supported by four implants: 2‐years prospective studyClinical Oral Implants Research, 2013
- Short Implant to Support Maxillary RestorationsJournal of Craniofacial Surgery, 2012
- The Positive Relationship Between Excess Cement and Peri‐Implant Disease: A Prospective Clinical Endoscopic StudyJournal of Periodontology, 2009
- Parameters affecting retentive force of electroformed double-crown systemsClinical Oral Investigations, 2009
- Tooth loss in the elderly and its association with nutritional status, socio-economic and lifestyle factorsActa Odontologica Scandinavica, 2007
- Immediate loading of single-tooth implants in the posterior regionThe Journal of Prosthetic Dentistry, 2005
- A preliminary investigation into the ultrastructure of dental calculus and associated bacteriaJournal of Clinical Periodontology, 2004
- Photoelastic stress analysis of implant-tooth connected prostheses with segmented and nonsegmented abutmentsThe Journal of Prosthetic Dentistry, 2003