Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Authors:
- R. LeahyRLR. Leahy
- S.R. CherrySCS.R. Cherry
- Zhenyu ZhouZZZhenyu Zhou
- 1 January 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 13 (4) , 687-701
Abstract
The authors describe conjugate gradient algorithms for reconstruction of transmission and emission PET images. The reconstructions are based on a Bayesian formulation, where the data are modeled as a collection of independent Poisson random variables and the image is modeled using a Markov random field. A conjugate gradient algorithm is used to compute a maximum a posteriori (MAP) estimate of the image by maximizing over the posterior density. To ensure nonnegativity of the solution, a penalty function is used to convert the problem to one of unconstrained optimization. Preconditioners are used to enhance convergence rates. These methods generally achieve effective convergence in 15-25 iterations. Reconstructions are presented of an (18)FDG whole body scan from data collected using a Siemens/CTI ECAT931 whole body system. These results indicate significant improvements in emission image quality using the Bayesian approach, in comparison to filtered backprojection, particularly when reprojections of the MAP transmission image are used in place of the standard attenuation correction factors.Keywords
This publication has 26 references indexed in Scilit:
- A modified expectation maximization algorithm for penalized likelihood estimation in emission tomographyIEEE Transactions on Medical Imaging, 1995
- Maximum Likelihood Preprocessing for Improved Filtered Back-Projection ReconstructionsJournal of Computer Assisted Tomography, 1994
- Bayesian estimation of transmission tomograms using segmentation based optimizationIEEE Transactions on Nuclear Science, 1992
- Vector-extrapolated fast maximum likelihood estimation algorithms for emission tomographyIEEE Transactions on Medical Imaging, 1992
- Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomographyIEEE Transactions on Medical Imaging, 1991
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priorsIEEE Transactions on Medical Imaging, 1989
- Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis TestingIEEE Transactions on Medical Imaging, 1987
- A Technique To Reject Scattered Radiation In PET Transmission Scans1986
- Maximum Likelihood Reconstruction for Emission TomographyIEEE Transactions on Medical Imaging, 1982