Application of Protective Stents in Endovascular Repair of Acute Complicated Stanford Type B Aortic Dissections
Authors:
- 1 April 2013
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 20 (2) , 210-218
Abstract
Purpose To describe the use of protective stents in the endovascular repair of acute complicated Stanford type B aortic dissections. Methods From 2009 to 2011, 33 patients (27 men; mean age 47 years, range 31–73) with acute complicated Stanford type B aortic dissection underwent thoracic endovascular aortic repair (TEVAR) assisted by protective stents. In all cases, the proximal and distal landing zones differed in size by >5 mm, and the primary entry tear was in the proximal descending aorta. A bare self-expanding stent (protective stent) was deployed initially at the intended distal landing site of the primary stent-graft in the true lumen. The intention was that the bare stent would prevent excessive dilation of the distal end of the stent-graft in the vicinity of the entry tear, thus avoiding intimal rupture. Results Successful stent deployment and sealing of the entry tear was achieved in all patients. The median diameter and length of the protective bare stents was 20.3 mm (range 18–24) and 72.7 mm (range 60–80), respectively, while the corresponding dimensions of the covered stent-grafts were 32.8 mm (range 26–40) and 157.4 mm (range 120–200 mm), respectively. There was no stent twisting, migration, of rupture of the false or true lumen. Computed tomography 1 week postoperatively demonstrated closure of the primary entry tear with thrombosis of the false lumen in all cases. No patients were lost to follow-up, which has ranged from 3 months to 3 years. No late endoleaks or stent complications, such as angulation, dislodgment, persistent leaks, branch obstruction, or stent-graft migration, have been observed, and there has been no chronic progressive true or false lumen dilatation, recurrences, or deaths. Conclusion Adjunctive use of a protective stent when treating acute Stanford type B aortic dissections in which the diameters of the proximal and distal landing zones differ by >5 mm is feasible and safe and provides good short-term outcomes.Keywords
This publication has 19 references indexed in Scilit:
- Midterm results after endovascular treatment of acute, complicated type B aortic dissection: The Talent Thoracic RegistryThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Endovascular Stent-Graft Placement or Open Surgery for the Treatment of Acute Type B Aortic Dissection: A Meta-AnalysisAnnals of Vascular Surgery, 2012
- Thoracic Endovascular Repair for Complicated Type B Acute Aortic Dissection with Distal MalperfusionThe Korean Journal of Thoracic and Cardiovascular Surgery, 2011
- Thoracic endovascular aortic repair with homemade stent grafts: Early and mid-term outcomesSurgery Today, 2011
- Report on the results of thoracic endovascular aortic repair for acute, complicated, type B aortic dissection at 30 days and 1 year from a multidisciplinary subcommittee of the Society for Vascular Surgery Outcomes CommitteeJournal of Vascular Surgery, 2011
- Stent Grafting–Related Acute Type B RedissectionVascular, 2008
- A study of aortic dimension in type B aortic dissectionInteractive CardioVascular and Thoracic Surgery, 2007
- Evidence suggests rigid aortic grafts increase systolic blood pressure: Results of a preliminary studyMedical Engineering & Physics, 2007
- Endovascular treatment of thoracic aortic diseases: Combined experience from the EUROSTAR and United Kingdom Thoracic Endograft registriesJournal of Vascular Surgery, 2004
- Endovascular Stent–Graft Placement for the Treatment of Acute Aortic DissectionNew England Journal of Medicine, 1999