Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses
Authors:
- R S de MolonRMR S de Molon
- R G BatitucciRBR G Batitucci
- R Spin-NetoRSR Spin-Neto
- G M PaquierGPG M Paquier
- C E SakakuraCSC E Sakakura
- G M TosoniGTG M Tosoni
- G ScafGSG Scaf
- 1 October 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 42 (9) , 20130235
Abstract
To evaluate the influence of soft-tissue simulation materials on dental and bone tissue radiographic densities using pixel intensity (PI) and digital subtraction radiography (DSR) analyses. 15 dry human mandibles were divided into halves. Each half was radiographed using a charge-coupled device sensor without a soft-tissue simulation material (Wm) and with 5 types of materials: acrylic (Ac), wax (Wx), water (Wt), wood (Wd) and frozen bovine tissue (Bt). Three thicknesses were tested for each material: 10 mm, 15 mm and 20 mm. The material was positioned in front of the mandible and the sensor parallel to the molar region. The radiation beam was perpendicular to the sensor at 30 cm focal spot-to-object distance. The digital images of the bone and dental tissue were captured for PI analyses. The subtracted images were marked with 14 landmark magnifications, and 2 areas of analyses were defined, forming the regions of interest. Shapiro-Wilk and Kruskal-Wallis tests followed by Dunn's post-test were used (p < 0.05). DSR showed that both the material type and the thickness tested influenced the gain of density in bone tissue (p < 0.05). PI analyses of the bone region did not show these differences, except for the lower density observed in the image without soft-tissue simulation material. In the dental region, both DSR and PI showed that soft-tissue simulators did not influence the density in these regions. This study showed that the materials evaluated and their thicknesses significantly influenced the density-level gain in alveolar bone. In dental tissues, there was no density-level gain with any soft-tissue material tested.Keywords
This publication has 32 references indexed in Scilit:
- Effect of tube potential and image receptor on the detection of natural proximal caries in primary teethClinical Oral Investigations, 2010
- In vitrocomparison of digital and conventional bitewing radiographs for the detection of approximal caries in primary teeth exposed and viewed by a new wireless handheld unitDentomaxillofacial Radiology, 2010
- Evaluation of automatic exposure control in a direct digital intraoral systemDentomaxillofacial Radiology, 2009
- Influence of homeopathic treatment with comfrey on bone density around titanium implants. A digital subtraction radiography study in ratsClinical Oral Implants Research, 2008
- Radiographic features of periodontal bone defects: evaluation of digitized imagesDentomaxillofacial Radiology, 2007
- In vitro assessment of local computed tomography for the detection of longitudinal tooth fracturesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Comparison of simulated periodontal bone defect depth measured in digital radiographs in dedicated and non-dedicated software systemsDentomaxillofacial Radiology, 2006
- Pixel intensity and fractal analyses: detecting osteoporosis in perimenopausal and postmenopausal women by using digital panoramic imagesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Accuracy of zoomed digital image in the detection of periodontal bone defect:in vitrostudyDentomaxillofacial Radiology, 2006
- Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesionsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1996