Imidazolium-based ionic liquid derivative/CuII complexes as efficient catalysts of the lucigenin chemiluminescence system and its application to H2O2 and glucose detection
- 11 July 2015
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (20) , 6127-6136
Abstract
The effects of six synthetic imidazolium-based ionic liquids (ILs) on the CuII-catalyzed chemiluminescence of lucigenin (Luc-CL) in the pH range 6.0–11 were investigated. Preliminary experiments found that the CL emission was strongly enhanced or inhibited in the presence of the ILs. The degree of enhancement or inhibition of the CL intensity in the presence of each IL was related to the molecular structure of the IL, the medium used, and the pH. The maximum enhancement of the CL intensity was observed at pH 9.0 (amplification factor = 443). This decrease in the pH at which maximum CL enhancement occurred and the substantial signal amplification of the Luc-CL may be related to a strong interaction between CuII and the imidazolium ring of superior ILs at this pH. Additionally, the formation of IL microdomains in semi-aqueous media permitted more solubility of the product yielded by the Luc-CL reaction (N-methylacridone), which could increase the CL intensity. To obtain consistent data on the catalytic efficiency of CuII in the presence of various ILs as well as the corresponding CL emission intensities, fluorescence quantum yields (Φ F) of lucigenin were measured under the same conditions. Comparison of the data pointed to the mechanism that controls the properties of Luc-CL in the presence of the CuII/IL complexes. Based on the catalytic effect of the CuII/IL complex and the measurement of the enzymatically generated H2O2, a novel, simple, and sensitive CL method for determining glucose with a detection limit (LoD) of 6.5 μM was developed. Moreover, this method was satisfactorily applied to the determination of glucose in human serum and urine samples. Graphical Abstract The lucigenin chemiluminescence assay for H2O2 and glucose using imidazolium–based ionic liquid derivatives/CuII complexes as efficient catalysts at pH 9.0 The lucigenin chemiluminescence assay for H2O2 and glucose using imidazolium–based ionic liquid derivatives/CuII complexes as efficient catalysts at pH 9.0Keywords
This publication has 61 references indexed in Scilit:
- Glucose oxidase enzyme inhibition sensors for heavy metals at carbon film electrodes modified with cobalt or copper hexacyanoferrateSensors and Actuators B: Chemical, 2013
- SBA-15-functionalized sulfonic acid confined acidic ionic liquid: a powerful and water-tolerant catalyst for solvent-free esterificationsChemical Communications, 2012
- CoFe2O4 magnetic nanoparticles as a peroxidase mimic mediated chemiluminescence for hydrogen peroxide and glucoseChemical Communications, 2011
- Platinum nanoparticle-catalyzed lucigenin–hydrazine chemiluminescenceJournal of Photochemistry and Photobiology A: Chemistry, 2011
- Chemiluminescence determination of chromium(III) and total chromium in water samples using the periodate-lucigenin reactionMicrochimica Acta, 2006
- Flow-Injection Chemiluminescence Determination of Cobalt Using a Cobalt(II) (1,10-Phenanthroline)3 Complex-Catalyzed Lucigenin-Periodate ReactionMicrochimica Acta, 2005
- Chemiluminescence at liquid–liquid interfaces. Enhanced chemiluminescence of lucigenin and long alkyl lucigenins.Journal of Photochemistry and Photobiology A: Chemistry, 1998
- Chemiluminescent enzymatic assay for cholesterol in serum using lucigeninAnalytica Chimica Acta, 1995
- Flow-injection determination of kanamycin by inhibition of the lucigenin—H2O2Co2+ systemAnalytica Chimica Acta, 1994
- Chemiluminescence in organized molecular assemblies: lucigenin derivatives containing long alkyl chains in micellar mediaAnalytica Chimica Acta, 1994