Scoliosis correction and epidural analgesia
Author:
- 1 November 1982
- journal article
- case report
- Published by Wiley in Anaesthesia
- Vol. 37 (11) , 1115-1117
Abstract
Summary: This case report illustrates the problems which may arise when an epidural block is used during an operation to correct a spinal deformity. In this case, the block was more profound and persistent than expected. This could have been due to spinal cord compression or to ischaemia following the correction with Harrington rods, so the rods had to be removed and re‐inserted later, after the paraparesis had resolved.Keywords
This publication has 5 references indexed in Scilit:
- Arterial Pressure Manipulation Alters Spinal Cord Function during Correction of ScoliosisAnesthesiology, 1981
- HARRINGTON ROD SPINAL FUSIONBritish Journal of Anaesthesia, 1979
- Intraoperative awakening to monitor spinal cord function during Harrington instrumentation and spine fusion. Description of procedure and report of three cases.Journal of Bone and Joint Surgery, 1978
- Acute neurological complications in the treatment of scoliosis. A report of the Scoliosis Research SocietyJournal of Bone and Joint Surgery, 1975
- Treatment of ScoliosisJournal of Bone and Joint Surgery, 1962