Image analysis methods for diffuse optical tomography
- 1 January 2006
- journal article
- review article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (3) , 033001-033001-16
Abstract
Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often presents a different problem, which requires contrast-detail analysis. This analysis shows that the minimum detectable sizes are in the range of 1/10 the outer diameter, whereas minimum detectable contrast values are in the range of 10 to 20% relative to the continuous background values. This is estimated for objects being in the center of the domain being imaged, and as the heterogeneous region becomes closer to the surface, the lower limit on size and contrast can become arbitrarily low and more dictated by hardware specifications. Finally, if human observer detection of abnormalities in the images is the goal, as is standard in most radiological practice, receiver operating characteristic (ROC) curve and location receiver operating characteristic curve (LROC) are used. Each of these three major areas of image interpretation and analysis are reviewed in the context of medical imaging as well as how they are used to quantify the performance of diffuse optical imaging of tissue.Keywords
This publication has 121 references indexed in Scilit:
- Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomographyProceedings of the National Academy of Sciences, 2006
- Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structureJournal of Biomedical Optics, 2005
- Experimental Fluorescence Tomography of Tissues With Noncontact MeasurementsIEEE Transactions on Medical Imaging, 2004
- Comparison of an amorphous silicon/cesium iodide flat‐panel digital chest radiography system with screen/film and computed radiography systems — A contrast‐detail phantom studyMedical Physics, 2001
- Contrast‐detail analysis for detection and characterization with near‐infrared diffuse tomographyMedical Physics, 2000
- Imaging Transgenic AnimalsAnnual Review of Biomedical Engineering, 1999
- Optical tomography in medical imagingInverse Problems, 1999
- Frequency‐domain optical mammography: Edge effect correctionsMedical Physics, 1996
- Optimized radial and angular positions in Monte Carlo modelingMedical Physics, 1994
- Properties of photon density waves in multiple-scattering mediaApplied Optics, 1993