Sensitive Human Interleukin 5 Impedimetric Sensor Based on Polypyrrole−Pyrrolepropylic Acid−Gold Nanocomposite
Authors:
- 23 October 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (22) , 8485-8492
Abstract
A sensitive impedimetric immunosensor was constructed by using an electropolymerized nanocomposite film containing polypyrrole (PPy), polypyrrolepropylic acid (PPa), and Au nanoparticles. The nanocomposite exhibits good stability, high porosity, high hydrophilicity, and efficient probe immobilization capability. In the film, PPa enhances the hydrophilicity while providing covalent probe attachment linkers, PPy promotes the conductivity and electroactivity, and Au nanoparticles result in good conductivity, high stability, and covalent binding linkers. These combined advantages significantly improve the detection sensitivity in comparison to the conventional methods. As a model, a human interleukin 5 (IL-5) immunosensor, an important sensor for disease pathology study, clinic diagnosis, and pharmaceutical research, was fabricated with the new nanocomposite film. Various optimization works were conducted to improve the detection sensitivity. With the optimal fabrication parameters, the detection limit for IL-5 was 10 fg/mL in phosphate buffered saline (PBS) and 1 pg/mL in 1% human serum with good specificity and a dynamic range of 3 orders of magnitude. This work demonstrates a new approach to develop a sensitive and labeless impedimetric immunosensor for potential broad applications in clinical diagnosis and drug discovery.Keywords
This publication has 52 references indexed in Scilit:
- An in situ electrochemical surface plasmon resonance immunosensor with polypyrrole propylic acid film: Comparison between SPR and electrochemical responses from polymer formation to protein immunosensingBiosensors and Bioelectronics, 2008
- Electrosynthesis and characterization of polypyrrole/Au nanocompositeElectrochimica Acta, 2007
- Sensitive Amperometric Immunosensing Using Polypyrrolepropylic Acid Films for Biomolecule ImmobilizationAnalytical Chemistry, 2006
- Electrochemical SensorsAnalytical Chemistry, 2006
- Electrochemical enzyme immunoassay using immobilized antibody on gold film with monitoring of surface plasmon resonance signalAnalytica Chimica Acta, 2002
- New label-free DNA recognition based on doping nucleic-acid probes within conducting polymer filmsAnalytica Chimica Acta, 1999
- Electroimmobilisation of sulphite oxidase into a polypyrrole film and its utilisation for flow amperometric detection of sulphiteAnalytica Chimica Acta, 1996
- Polypyrrole-based potentiometric biosensor for ureaAnalytica Chimica Acta, 1993
- Pulse damperometric detection of proteins using antibody containing conducting polymersAnalytica Chimica Acta, 1993
- Cation recognition properties of polypyrrole 3-substituted by azacrown ethersJournal of the Chemical Society, Chemical Communications, 1993