Signal to Noise Ratio of Monolithic Scintillator Detectors for High Resolution PET
- 1 January 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 3027-3031
Abstract
Monolithic scintillator detectors, consisting of several cm3 of scintillating material coupled to one or more Hamamatsu S8550 avalanche photodiode (APD) arrays, have been proposed as detectors for high resolution positron emission tomography (PET). These detectors eliminate the dead space caused by reflective material between crystal pixels, and provide good depth of interaction (DOI) information. The entry point of impinging annihilation photons on the front surface of the detector is derived from the scintillation light distribution on the APD array(s). In this work, the various contributions to the energy and timing resolutions were analysed, as well as the influence of several contributions to the spatial resolution. Energy resolutions of around 11.5% FWHM at 511 keV were measured, the major part of which was found to be due to the intrinsic photon variance of the scintillator. A timing resolution of 1.6 ns FWHM was measured against a BaF2-PMT detector. The timing resolution was found to be strongly gain dependent. Spatial resolutions of around 1.75 mm FWHM were measured, fairly independent of the APD gain. This figure still needs to be corrected for the ~0.9 mm FWHM measurement beam.Keywords
This publication has 8 references indexed in Scilit:
- Using Cramer-Rao theory combined with Monte Carlo simulations for the optimization of monolithic scintillator PET detectorsIEEE Transactions on Nuclear Science, 2006
- Experimental characterization of monolithic-crystal small animal PET detectors read out by APD arraysIEEE Transactions on Nuclear Science, 2006
- Performance of APD-Based Monolithic-Crystal Detectors for Small Animal PET2006
- Measuring the absolute light yield of scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2005
- Characterisation of arrays of avalanche photodiodes for small animal positron emission tomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Non-proportionality in the scintillation response and the energy resolution obtainable with scintillation crystalsIEEE Transactions on Nuclear Science, 1995
- A method for the determination of the noise parameters in preamplifying systems for semiconductor radiation detectorsReview of Scientific Instruments, 1993
- Suboptimal filtering of 1/ƒ-noise in detector charge measurementsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990