Computer-assisted total knee replacement in patients with arthritis and a recurvatum deformity
Authors:
- 1 May 2012
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 94-B (5) , 642-647
Abstract
We retrospectively reviewed the records of 1150 computer-assisted total knee replacements and analysed the clinical and radiological outcomes of 45 knees that had arthritis with a pre-operative recurvatum deformity. The mean pre-operative hyperextension deformity of 11° (6° to 15°), as measured by navigation at the start of the operation, improved to a mean flexion deformity of 3.1° (0° to 7°) post-operatively. A total of 41 knees (91%) were managed using inserts ≤ 12.5 mm thick, and none had mediolateral laxity > 2 mm from a mechanical axis of 0° at the end of the surgery. At a mean follow-up of 26.4 months (13 to 48) there was significant improvement in the mean Knee Society, Oxford knee and Western Ontario and McMaster Universities Osteoarthritis Index scores compared with the pre-operative values. The mean knee flexion improved from 105° (80° to 125°) pre-operatively to 131° (120° to 145°), and none of the limbs had recurrent recurvatum.These early results show that total knee replacement using computer navigation and an algorithmic approach for arthritic knees with a recurvatum deformity can give excellent radiological and functional outcomes without recurrent deformity.Keywords
This publication has 18 references indexed in Scilit:
- High-flexion TKA in patients with a minimum of 120 degrees of pre-operative knee flexion: outcomes at six years of follow-upInternational Orthopaedics, 2010
- Lateral Epicondylar Osteotomy Using Computer Navigation in Total Knee Arthroplasty for Rigid Valgus DeformitiesThe Journal of Arthroplasty, 2010
- Navigational predictors in determining the necessity for collateral ligament release in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2009
- Comparison of Limb and Component Alignment Using Computer-Assisted Navigation Versus Image Intensifier–Guided Conventional Total Knee ArthroplastyThe Journal of Arthroplasty, 2007
- The use of the Oxford hip and knee scoresThe Journal of Bone and Joint Surgery. British volume, 2007
- Optimization of the Posterior Condylar Offset, Tibial Slope, and Condylar Roll-back in Total Knee ArthroplastyThe Journal of Arthroplasty, 2006
- Genu Recurvatum in Total Knee ReplacementClinical Orthopaedics and Related Research, 2003
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Factors affecting range of flexion after total knee arthroplastyJournal of Orthopaedic Science, 2001
- Influence of prosthetic joint line position on knee kinematics and patellar positionThe Journal of Arthroplasty, 1991