Abstract
Magnetic induction tomography (MIT) is a new and emerging type of tomography technique that is able to map the passive electromagnetic properties (in particular conductivity) of an object. Excitation coils are used to induce eddy currents in the medium, and the magnetic field produced by the induced eddy current is then sensed by the receiver coils. Because of its non-invasive and contactless feature, it becomes an attractive technique for many applications (especially in biomedical area) compared to traditional contact electrode-based electrical impedance tomography. Due to the low contrast in conductivity between biological tissues, an accurate and stable hardware system is necessary. Most MIT systems in the literature employ external signal generators, power amplifiers and highly stable down-conversion electronics to obtain a satisfactory phase measurement. However, this would increase design complexity substantially. In this paper, a National Instrument-based MIT system is developed at the University of Bath, aiming for biomedical applications. The system utilizes National Instrument products to accomplish all signal driving, switching and data acquisition tasks, which ease the system design whilst providing satisfactory performance. This paper presents a full-scaled medical MIT system, from the sensor and system hardware design, eddy current model verification to the image reconstruction software: the performance of this MIT instrumentation system is characterized in detail, including the system accuracy and system stability. The methods of solving eddy current problem are presented. The reconstructed images of detecting the presence of saline solutions are also included in this paper, which show the capability of national instrument products to be developed into a full-scaled biomedical MIT system, by demonstrating the practical experimental results.Keywords
This publication has 23 references indexed in Scilit:
- GREIT: a unified approach to 2D linear EIT reconstruction of lung imagesPhysiological Measurement, 2009
- Residual capacitive coupling and the measurement of permittivity in magnetic induction tomographyPhysiological Measurement, 2007
- A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibrationPhysiological Measurement, 2006
- Hardware and software design for an electromagnetic induction tomography (EMT) system for high contrast metal process applicationsMeasurement Science and Technology, 2005
- Regularization on Ill-Posed Source Terms in FEM Computation Using Two Magnetic Vector PotentialsIEEE Transactions on Magnetics, 2004
- Magnetic induction tomographyMeasurement Science and Technology, 2001
- An edge finite element eddy current formulation using a reduced magnetic and a current vector potentialIEEE Transactions on Magnetics, 2000
- Magnetic induction tomography: experimental realizationPhysiological Measurement, 2000
- Edge element formulations of eddy current problemsComputer Methods in Applied Mechanics and Engineering, 1999
- On the use of the magnetic vector potential in the finite-element analysis of three-dimensional eddy currentsIEEE Transactions on Magnetics, 1989