Validation of Spectral Domain Optical Coherence Tomographic Doppler Shifts Using an In Vitro Flow Model
Open Access
- 1 February 2009
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 50 (2) , 702-706
Abstract
Purpose. To validate velocity measurements produced by spectral domain optical coherence tomography (SD-OCT) in an in vitro laminar flow model. methods. A 30-mL syringe filled with skim milk was inserted into a syringe pump. Intravenous (IV) tubing connected the syringe within the pump to a glass capillary tube (internal diameter, 0.579 mm) shallowly embedded in agarose gel, then to a collection reservoir. SD-OCT imaging was performed with an anterior segment eye scanner and optics engine coupled with a 100-nm bandwidth broadband superluminescent diode. Scan density of 128 × 128 A-scans was spread over a 4 × 4 mm area, and each A-scan was 2 mm in length. Fifteen sequential stationary A-scans were obtained at each 128 × 128 position, and Doppler shifts were calculated from temporal changes in phase. The beam-to-flow vector Doppler angle was determined from three-dimensional scans. results. In all reflectance and Doppler images, a clear laminar flow pattern was observed, with v max appearing in the center of the flow column. Phase wrapping was observed at all measured flow velocities, and fringe washout progressively shattered reflectance and phase signals beyond the Nyquist limit. The observed percentages of the velocity profile at or below Nyquist frequency was highly correlated with the predicted percentages (R 2 = 0.934; P = 0.007). conclusions. SD-OCT provides objective Doppler measurements of laminar fluid flow in an in vitro flow system in a range up to the Nyquist limit.Keywords
This publication has 11 references indexed in Scilit:
- In vivo total retinal blood flow measurement by Fourier domain Doppler optical coherence tomographyJournal of Biomedical Optics, 2007
- Real-time spectral domain Doppler optical coherence tomography and investigation of human retinal vessel autoregulationJournal of Biomedical Optics, 2007
- Real-time measurement of in vitro flow by Fourier-domain color Doppler optical coherence tomographyOptics Letters, 2004
- Motion artifacts in optical coherence tomography with frequency-domain rangingOptics Express, 2004
- Reproducibility and clinical application of a newly developed stabilized retinal laser Doppler instrumentAmerican Journal of Ophthalmology, 2003
- In vivo human retinal imaging by Fourier domain optical coherence tomographyJournal of Biomedical Optics, 2002
- Spectroscopic optical coherence tomographyOptics Letters, 2000
- Optical Coherence TomographyScience, 1991
- A comparison between mean blood velocities and center-line red cell velocities as measured with a mechanical image streaking velocitometerMicrovascular Research, 1979
- On-line volume flow rate and velocity profile measurement for blood in microvesselsMicrovascular Research, 1974