Highly Sensitive Protein Detection by Asymmetric Mach–Zehnder Interferometry for Biosensing Applications
- 11 June 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 3 (7) , 4566-4572
Abstract
The sensitivity and performance of an asymmetric Mach–Zehnder interferometer (aMZI) were compared to those of quartz crystal microbalance with dissipation (QCM-D). The binding of streptavidin to sensor chips coated with poly-l-lysine (PLL), modified with biotin and oligoethyleneglycol (OEG) (PLL-biotin), was used to compare the binding signals obtained from both technologies. PLL-biotin proved to be an efficient method to add bioreceptors to both the QCM-D and aMZI chips. The final, saturated value of streptavidin binding was compared with those from aMZI (253 ng cm–2) and QCM-D (460 ng cm–2). These values were then used to evaluate that 45% of the measured streptavidin mass in the QCM-D came from hydrodynamically coupled water. Importantly, the signal-to-noise ratio of the aMZI was found to be 200 times higher than that of the QCM-D. These results indicate the potential of the aMZI platform for highly sensitive and accurate biosensing applications.Keywords
Funding Information
- European Commission (Biomeander)
- OP Oost (Biomeander)
This publication has 36 references indexed in Scilit:
- Asymmetric Mach–Zehnder Interferometer Based Biosensors for Aflatoxin M1 DetectionBiosensors, 2016
- Functionalized Polyelectrolytes Assembling on Nano‐BioFETs for Biosensing ApplicationsAdvanced Functional Materials, 2015
- Integrated planar optical waveguide interferometer biosensors: A comparative reviewBiosensors and Bioelectronics, 2014
- Highly sensitive Mach–Zehnder interferometer biosensor based on silicon nitride slot waveguideSensors and Actuators B: Chemical, 2013
- Integrated optical devices for lab‐on‐a‐chip biosensing applicationsLaser & Photonics Reviews, 2011
- Glucose Biosensors: An Overview of Use in Clinical PracticeSensors, 2010
- Characterization of Streptavidin Binding to Biotinylated, Binary Self-Assembled Thiol Monolayers—Influence of Component Ratio and SolventLangmuir, 2010
- A label-free affinity sensor with compensation of unspecific protein interaction by a highly sensitive integrated optical Mach–Zehnder interferometer on siliconSensors and Actuators B: Chemical, 1997
- Design of new integrated optical substrates for immuno-analytical applicationsAnalytical and Bioanalytical Chemistry, 1994
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959