μFlow-injection–ICP collision cell MS determination of molybdenum, nickel and vanadium in petroleum samples using a modified total consumption micronebulizer
- 5 October 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 22 (1) , 88-92
Abstract
An interface based on a total consumption micronebulizer was developed for the introduction of xylene solutions into ICP MS. The increase in the nebulizer capillary diameter and the elimination of the internal connections reduced the problem of clogging, pressure instability and memory effects. The xylene carrier could be introduced for several hours at a rate of 30 μl min−1. The sample (2.5 μl) was injected into the carrier flow to produce peaks of 5 s at half-height (20 s at the base) which allowed a throughput of ca. 100 h−1 for the simultaneous determination of Mo, Ni and V. Calibration curves with good linearity (R2 > 0.999) over at least three orders of magnitude and detection limits at the sub-ng ml−1 levels were obtained. The method was validated by the analysis of a sample by an independent (ICP AES) method and by the analysis of a NIST CRM 1085c lubricating oil material. The use of a helium-pressurized collision cell was essential to obtain good accuracy for Ni and V but was not required for Mo.Keywords
This publication has 15 references indexed in Scilit:
- Direct Trace and Ultra-Trace Metals Determination in Crude Oil and Fractions by Inductively Coupled Plasma Mass SpectrometryJournal of ASTM International, 2005
- Geochemical implications of trace elements and sulfur in the saturate, aromatic and resin fractions of crude oil from the Mara and Mara Oeste fields, VenezuelaFuel, 2004
- Introduction of high carbon content solvents into inductively coupled plasma mass spectrometry by a direct injection high efficiency nebuliserAnalytical and Bioanalytical Chemistry, 2003
- Trace element determination in crude oil and its fractions by inductively coupled plasma mass spectrometry using ultrasonic nebulization of toluene solutionsSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Noise characteristics and analytical precision of a direct injection high efficiency and micro concentric nebuliser for sample introduction in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2002
- Evaluation of a direct injection high-efficiency nebulizer (DIHEN) by comparison with a high-efficiency nebulizer (HEN) coupled to a cyclonic spray chamber as a liquid sample introduction system for ICP-AESJournal of Analytical Atomic Spectrometry, 2001
- Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisationJournal of Analytical Atomic Spectrometry, 2000
- Use of molecular parameters and trace elements in oil-oil correlation studies, Barinas sub-basin, VenezuelaOrganic Geochemistry, 1998
- Use of an ultrasonic nebulizer with membrane desolvation for analysis of volatile solvents by inductively coupled plasma atomic emission spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Characterization and Optimization of a Direct Injection Nebulizer for Introduction of Organic Solvents and Volatile Analyte Species into an Inductively Coupled PlasmaApplied Spectroscopy, 1990