The development of noninvasive approaches for brain tumor diagnosis and monitoring continues to be a major medical challenge. Although blood-based liquid biopsy has received considerable attention in various cancers, limited progress has been made for brain tumors, at least partly due to the hindrance of tumor biomarker release into the peripheral circulation by the blood-brain barrier. Focused ultrasound (FUS) combined with microbubbles induced BBB disruption has been established as a promising technique for noninvasive and localized brain drug delivery. Building on this established technique, we propose to develop FUS-enabled liquid biopsy technique (FUS-LBx) to enhance the release of brain tumor biomarkers (e.g., DNA, RNA, and proteins) into the circulation. The objective of this study was to demonstrate that FUS-LBx could sufficiently increase plasma levels of brain tumor biomarkers without causing hemorrhage in the brain. Mice with orthotopic implantation of enhanced green fluorescent protein (eGFP)-transfected murine glioma cells were treated using magnetic resonance (MR)-guided FUS system in the presence of systemically injected microbubbles at three peak negative pressure levels (0.59, 1.29, and 1.58 MPa). Plasma eGFP mRNA levels were quantified with the quantitative polymerase chain reaction (qPCR). Contrast-enhanced MR images were acquired before and after the FUS sonication. FUS at 0.59 MPa resulted in an increased plasma eGFP mRNA level, comparable to those at higher acoustic pressures (1.29 MPa and 1.58 MPa). Microhemorrhage density associated with FUS at 0.59 MPa was significantly lower than that at higher acoustic pressures and not significantly different from the control group. MRI analysis revealed that post-sonication intratumoral and peritumoral hyperenhancement had strong correlations with the level of FUS-induced biomarker release and the extent of hemorrhage. This study suggests that FUS-LBx could be a safe and effective brain-tumor biomarker release technique, and MRI could be used to develop image-guided FUS-LBx.Keywords
Funding Information
- National Institutes of Health (R01MH116981)
- National Institutes of Health (R01EB27223)
- National Institutes of Health (UL1TR002345)
This publication has 61 references indexed in Scilit:
- The kinetics of blood brain barrier permeability and targeted doxorubicin delivery into brain induced by focused ultrasoundJournal of Controlled Release, 2012
- Concurrent blood–brain barrier opening and local drug delivery using drug-carrying microbubbles and focused ultrasound for brain glioma treatmentBiomaterials, 2012
- Optimization of the Ultrasound-Induced Blood-Brain Barrier OpeningTheranostics, 2012
- Noninvasive and localized neuronal delivery using short ultrasonic pulses and microbubblesProceedings of the National Academy of Sciences, 2011
- Multi-Modality Safety Assessment of Blood-Brain Barrier Opening Using Focused Ultrasound and Definity Microbubbles: A Short-Term StudyUltrasound in Medicine & Biology, 2010
- Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in MiceIn VivoIEEE Transactions on Biomedical Engineering, 2009
- Physical Principles of Microbubbles for Ultrasound Imaging and TherapyCerebrovascular Diseases, 2009
- Epidemiology of Brain TumorsNeurologic Clinics, 2007
- Noninvasive localized delivery of Herceptin to the mouse brain by MRI-guided focused ultrasound-induced blood–brain barrier disruptionProceedings of the National Academy of Sciences of the United States of America, 2006
- Cavitation-induced risks associated with contrast agents used in ultrasonographyEuropean Journal of Ultrasound, 1997