Controlled Laboratory Investigations of Wellbore Concentration Response to Pumping
- 1 January 2000
- journal article
- Published by Wiley in Groundwater
- Vol. 38 (1) , 121-128
Abstract
The relationship between the ground water sample and the surrounding ground water environment is controlled by wellborn flow and mixing that carry ground water to the sampling device. Controlled laboratory conditions and uniform inflow and inflowing concentration allowed detailed investigations of wellbore concentration responses to pump‐induced flow and mixing independent of external complicating influences. During pumping from the top of the screen, the results agreed with wellbore flow theory except for high‐frequency, high‐amplitude concentration fluctuations and mixing with the blank casing due to slight density contrasts (∼0.005%). Concentration fluctuations indicated partial mixing of ground water with well water and declining concentrations in the blank casing indicated that convection due to the slight density contrast overcame pump‐induced velocities. During pumping from the bottom of the well, opposing forces of buoyancy and pumping produced small‐scale cumulative mixing as the ground water from different portions of the screen approached the pump. Even during low‐flow pumping (i.e., 220 mL/min), 5% of the water was prepurge well water after five well volumes were pumped. In the field the density contrasts that resulted in these mixing processes might be caused by a slight cooling of the wellhead or a slight increase in temperature with depth (>0.2°C/m). If the temperature gradient was more pronounced, the convective mixing of screen water with the potentially altered casing water would be more thorough and sampling without mixing would not be possible. If the temperature gradient is stable or if the water in the blank casing is not significantly altered, casing water mixing will not present a problem.Keywords
This publication has 16 references indexed in Scilit:
- Sample Concentration Response to Laminar Wellbore Flow: Implications to Ground Water Data VariabilityGroundwater, 2000
- Bias in Ground‐Water Data Caused by Well‐Bore Flow in Long‐Screen WellsGroundwater, 1996
- Reproducible Well‐Purging Procedures and VOC Stabilization Criteria for Ground‐Water SamplingGroundwater, 1994
- Effects of Small‐Scale Vertical Variations in Well‐Screen Inflow Rates and Concentrations of Organic Compounds on the Collection of Representative Ground‐Water‐Quality SamplesGroundwater, 1993
- Passive sampling of groundwater monitoring wells without purging: multilevel well chemistry and tracer disappearanceJournal of Contaminant Hydrology, 1993
- Mass balance evaluation of monitoring well purging: Part II. Field tests at a gasoline contamination siteJournal of Contaminant Hydrology, 1991
- Mass balance evaluation of monitoring well purging: Part I. Theoretical models and implications for representative samplingJournal of Contaminant Hydrology, 1991
- Importance of closely spaced vertical sampling in delineating chemical and microbiological gradients in groundwater studiesJournal of Contaminant Hydrology, 1991
- Application of Temperature and Electrical‐Conductivity Logging in Ground Water MonitoringGroundwater Monitoring & Remediation, 1989
- Details of Hydrochemical Variations in Flowing WellsGroundwater, 1980