Surface adjustment of the IRAM 30 m radio telescope
Authors:
- 2 February 2009
- journal article
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 3 (1) , 99-108
Abstract
The techniques used to set and stabilise the surface of the IRAM 30 m radio telescope to a final root mean square accuracy of about 50 µm are described. This involved both phase retrieval and phase coherent holography using a variety of radiation sources at several frequencies. A finite-element model was utilised in improving the temperature control system for the telescope structure. The factors influencing the ultimate surface accuracy are discussed.Keywords
This publication has 9 references indexed in Scilit:
- Errors in near-field radioholographyIET Microwaves, Antennas & Propagation, 2007
- Calculated thermal behavior of ventilated high precision radio telescopesIEEE Antennas and Propagation Magazine, 2006
- Repetitive radio reflector surface deformationsIEEE Transactions on Antennas and Propagation, 2005
- Improvement of the IRAM 30-m telescope from temperature measurements and finite-element calculationsIEEE Transactions on Antennas and Propagation, 2005
- Design parameters and measured performance of the IRAM 30-m Millimeter Radio TelescopeProceedings of the IEEE, 1994
- Astigmatism in reflector antennas: measurement and correctionIEEE Transactions on Antennas and Propagation, 1994
- Internal twist and least-squares adjustment of four-cornered surface plates for reflector antennasIEEE Transactions on Antennas and Propagation, 1981
- Gravitational deformation and astigmatism of tiltable radio telescopesIEEE Transactions on Antennas and Propagation, 1975
- Antenna tolerance theory—A reviewProceedings of the IEEE, 1966