Dopant compensation in alloyed CH3NH3PbBr3−xClx perovskite single crystals for gamma-ray spectroscopy
- 3 July 2017
- journal article
- research article
- Published by Springer Nature in Nature Materials
- Vol. 16 (8) , 826-833
Abstract
Organic–inorganic halide perovskites (OIHPs) bring an unprecedented opportunity for radiation detection with their defect-tolerance nature, large mobility–lifetime product, and simple crystal growth from solution. Here we report a dopant compensation in alloyed OIHP single crystals to overcome limitations of device noise and charge collection, enabling γ-ray spectrum collection at room temperature. CH3NH3PbBr3 and CH3NH3PbCl3 are found to be p-type and n-type doped, respectively, whereas dopant-compensated CH3NH3PbBr2.94Cl0.06 alloy has over tenfold improved bulk resistivity of 3.6 × 109 Ω cm. Alloying also increases the hole mobility to 560 cm2 V−1 s−1, yielding a high mobility–lifetime product of 1.8 × 10−2 cm2 V−1. The use of a guard ring electrode in the detector reduces the crystal surface leakage current and device dark current. A distinguishable 137Cs energy spectrum with comparable or better resolution than standard scintillator detectors is collected under a small electric field of 1.8 V mm−1 at room temperature.Keywords
This publication has 38 references indexed in Scilit:
- Enhanced gamma ray sensitivity in bismuth triiodide sensors through volumetric defect controlApplied Physics Letters, 2016
- Thin Insulating Tunneling Contacts for Efficient and Water‐Resistant Perovskite Solar CellsAdvanced Materials, 2016
- X-ray imaging with scintillator-sensitized hybrid organic photodetectorsNature Photonics, 2015
- Efficient planar heterojunction perovskite solar cells by vapour depositionNature, 2013
- Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image SensorsSensors, 2011
- Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical ApplicationsSensors, 2009
- Calculation of peak-to-total ratios for high purity germanium detectors using Monte-Carlo modelingJournal of Radioanalytical and Nuclear Chemistry, 2005
- CdZnTe and CdTe materials for X‐ray and gamma ray radiation detector applicationsPhysica Status Solidi (b), 2004
- Application of X‐ray microscopy in analysis of living hydrated cellsThe Anatomical Record, 2002
- Cadmium zinc telluride and its use as a nuclear radiation detector materialMaterials Science and Engineering: R: Reports, 2001