Optimization of Temperature Measurement Method for High-Pressure Gas Flow Standard Facility Based on Sonic Nozzle Array
Open Access
Abstract
To improve the accuracy of the wind tunnel test, relying on the high-pressure gas source of the China Aerodynamic Research and Development Center, a secondary flow standard facility based on a sonic nozzle array was developed, with a pressure range of (1~6) MPa and a flow range of (0.12~5.55) kg/s. Currently, most facilities use the average temperature measured by the temperature array to represent the upstream temperature of the sonic nozzle array. However, the small flow calibration test results showed that the maximum temperature difference upstream of the standard sonic nozzle array was 1.97 K, and the temperature field upstream of the sonic nozzle array showed non-uniformity, so the above method cannot accurately obtain the upstream temperature. To solve this problem, each nozzle used in the standard sonic nozzle array was accurately measured by temperature sensors. The uncertainty of the facility and the discharge coefficient of the calibrated nozzle between the two methods were compared. The results showed that compared with the discharge coefficient obtained using the temperature sensor array of 0.9902, the accurate measurement of 0.9904 was closer to the National Institute of Metrology, China (NIM) traceable result of 0.9907, and the relative uncertainty of the facility was reduced from 0.124% (k = 2) to 0.120% (k = 2).Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (52306056, 12234015)
- National Natural Science Foundation of China (52306056, 12234015)
This publication has 10 references indexed in Scilit:
- Surface Pressure Measurement of Truncated, Linear Aerospike Nozzles Utilising Secondary Injection for Aerodynamic Thrust VectoringAerospace, 2024
- Investigation of Spray Characteristics for Detonability: A Study on Liquid Fuel Injector and Nozzle DesignAerospace, 2024
- Correction for the temperature effects in a pVTt gas flow primary standard employing a dynamic methodMeasurement, 2022
- Key Parameters of a Design for a Novel Reflux Subsonic Low-Density Dust Wind TunnelAerospace, 2022
- The Thermal Effect on Discharge Coefficient of Sonic Nozzle Based on Reconstructed Body Temperature Distribution by Improved SOR MethodIEEE Transactions on Instrumentation and Measurement, 2021
- Blow-down calibration of a large ultrasonic flow meterFlow Measurement and Instrumentation, 2021
- Humidity effect on the calibration of discharge coefficients of critical flow Venturi nozzles in a pVTt facilityFlow Measurement and Instrumentation, 2015
- Flow characteristics of hydrogen gas through a critical nozzleInternational Journal of Hydrogen Energy, 2014
- The Size Effect on Critical Back Pressure Ratio for Sonic Nozzles2009
- Gas flowmeter calibrations with the 26m^3 PVTt standard2004