Abstract
Objective In a common cavity (CC) deformity, the cochlea and vestibule are confluent to form a single cavity without internal architecture, and distribution of auditory neuronal tissue is unclear. The purposes of this study are to reveal the spatial distribution of auditory neuronal tissue in CC deformity using electrically evoked auditory brainstem response (EABR) during cochlear implantation. Study Design Retrospective case review. Setting Cochlear implant (CI) center at a tertiary referral hospital. Patients Five patients with CC deformity who underwent cochlear implantation and intraoperative EABR testing. Main Outcome Measures Spatial distribution of electrodes that elicited an evoked wave V (eV) in EABR testing was evaluated in each CC deformity. Results Electrically evoked auditory brainstem response testing demonstrated that electrodes attached on the inner wall of the anteroinferior cavity of the CC deformity successfully elicited a reproducible eV in all cases, and the latency of each eV was an approximately 4 ms, which is similar to those reported in patients without an inner ear malformation. Interestingly, in Case 1 with the lowest percentage of eV-positive electrodes (31.8%), CI-aided audiometric thresholds were changed, depending on the frequency allocation to eV-positive electrodes in the programming. Cochlear implant–mediated facial nerve stimulation was observed in 3 of 5 cases, and results of EABR testing were useful for optimizing the device program to decrease facial nerve stimulation without sacrificing CI-mediated auditory performance. Conclusion The results of EABR testing suggested that auditory neuronal elements are distributed to the anteroinferior part of CC deformity, mainly around or near the inner wall of the cavity. In cases with CC deformity, EABR testing is useful to achieve the optimal electrode array placement and to adjust programming parameters of the implanted device, which might be essential to maximize CI outcomes and to decrease facial nerve stimulation.Keywords
This publication has 25 references indexed in Scilit:
- Audiological and surgical evidence for the presence of a third window effect for the conductive hearing loss in DFNX2 deafness irrespective of types of mutationsEuropean Archives of Oto-Rhino-Laryngology, 2013
- Spectrum of Temporal Bone Abnormalities in Patients with Waardenburg Syndrome andSOX10MutationsAmerican Journal of Neuroradiology, 2012
- CHD7 Mutational Analysis and Clinical Considerations for Auditory Rehabilitation in Deaf Patients with CHARGE SyndromePLOS ONE, 2011
- Evaluation of Objective Test Techniques in Cochlear Implant Users With Inner Ear MalformationsOtology & Neurotology, 2011
- Cochlear Implantation in Inner Ear Malformations — A Review ArticleCochlear Implants International, 2010
- SLC26A4 mutations are associated with a specific inner ear malformationInternational Journal of Pediatric Otorhinolaryngology, 2007
- Cochlear Implantation in Children With Anomalous Cochleovestibular AnatomyThe Laryngoscope, 2005
- A New Classification for Cochleovestibular MalformationsThe Laryngoscope, 2002
- Cochlear Implantation in Common Cavity Malformations Using a Transmastoid Labyrinthotomy ApproachThe Laryngoscope, 1997
- Congenital malformations of the inner ear: A classification based on embryogenesisThe Laryngoscope, 1987