Evaluating key ultrasound findings and their correlations with hip joint aspiration and prosthetic joint infection diagnosis following total hip arthroplasty
- 12 May 2025
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (10) , 2139-2148
Abstract
Objective To evaluate the association between specific ultrasound findings with the success of hip joint aspiration and the presence of joint infection in patients with hip arthroplasty. Materials and methods 138 patients who underwent ultrasound-guided aspiration were analyzed, focusing on hip joint capsular thickness, joint fluid echogenicity, synovial component visualization, and vascularity. These parameters were evaluated for their correlation with technically successful aspiration and infection status, using clinical data and the modified Musculoskeletal Infection Society (MSIS) criteria. Intra- and inter-reader reliability was also assessed for all measured parameters. Results Capsular thickness with a cutoff of 10 mm or greater, showed strong associations with technically successful aspiration (p = 0.0001) and joint infection (p = 0.0005), with high intra- and inter-observer reliability. Fluid echogenicity, when categorized as hypoechoic and moderate/heterogeneous, also showed significant associations with technically successful aspiration (p = 0.0001) and joint infection (p = 0.0009). While visualization of the synovial component did not correlate with aspiration outcomes (p = 0.24), it demonstrated a significant association with joint infection (p = 0.0007). Vascularity showed no significant correlation with technically successful aspiration (p = 0.22) or infection (p = 0.05). Conclusion Ultrasound is valuable in measuring variables that can be associated with a technically successful aspiration and the presence of prosthetic joint infection in patients with a history of total hip arthroplasty. Capsular thickness, particularly at a 10 mm cutoff, emerged as a sensitive and quantifiable parameter that can improve pre-procedural assessment accuracy. While other findings, such as fluid echogenicity and synovial component visualization showed potential, they are best interpreted alongside other clinical and imaging data.Keywords
This publication has 30 references indexed in Scilit:
- Imaging of hip arthroplastyEuropean Journal of Radiology, 2012
- Clinical and Radiologic Predictive Factors of Septic Hip ArthritisAmerican Journal of Roentgenology, 2012
- Clinical indications for musculoskeletal ultrasound: A Delphi-based consensus paper of the European society of musculoskeletal radiologyEuropean Radiology, 2012
- Validity of Preoperative Ultrasound-Guided Aspiration in the Revision of Hip ProsthesisUltrasound in Medicine & Biology, 2011
- Anatomical distribution of synovitis in knee osteoarthritis and its association with joint effusion assessed on non-enhanced and contrast-enhanced MRIOsteoarthritis and Cartilage, 2010
- The operation of the century: total hip replacementThe Lancet, 2007
- Accuracy of Joint Aspiration for the Preoperative Diagnosis of Infection in Total Hip ArthroplastyThe Journal of Arthroplasty, 2006
- Detection of infection in loosened hip prostheses: efficacy of sonography.American Journal of Roentgenology, 1994
- What Is the Right Rate for Total Hip Arthroplasty?Mayo Clinic Proceedings, 1993
- Total Hip and Total Knee ReplacementNew England Journal of Medicine, 1990