Development of prosthetic foot with an adjustable rollover shape for low-activity amputees (K-level 1–2)
- 24 October 2025
- journal article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 240 (1) , 3-15
Abstract
This research proposes a new prosthetic foot design with an adjustable rollover mechanism for low-activity amputees (K-levels 1–2) to improve walking symmetry and provide a more natural and comfortable walking experience. The design considers key factors such as foot length, weight, and height, with height being an essential factor affecting the rollover radius. The prosthetic foot was developed with adjustable rollover radii to accommodate different height categories. The strength and rollover radius were verified through finite element analysis with ANSYS 2021R2. Simulation results showed that the dorsiflexion angle ranged from 10.2° to 11.5°, increasing progressively from D00 to D10 and D11. A prototype was fabricated and evaluated in the single-subject pilot study to assess its effectiveness in improving gait symmetry using the symmetry index. The subject was a 62-year-old male (K-level 2) with a weight of 59 kg and a height of 159 cm. The results indicate that the prosthetic foot can adjust the rollover radius to 289, 297, and 323 mm, with the symmetry index improving as the rollover radius increases. The symmetry index of rollover radius for the prosthetic foot with rollover radius of 289, 297, and 323 mm, and SACH foot are 0.03%, −0.77%, −7.12%, and −11.62%, respectively. And the symmetry index of step time for the prosthetic foot with rollover radius of 289, 297, and 323 mm, and SACH foot are −4.14%, −11.07%, −18.19%, and −21.30%, respectively. In conclusion, an adjustable rollover prosthetic foot for low-activity amputees has developed. The single-subject pilot study showed that the symmetry index of the prosthetic foot with 289 mm rollover radius was better than the SACH foot in terms of rollover radius and step time of 99.7% and 80.5%, respectively.Keywords
This publication has 39 references indexed in Scilit:
- Analysis of 1.2 million foot scans from North America, Europe and AsiaScientific Reports, 2019
- Isotropic and anisotropic elasticity and yielding of 3D printed materialComposites Part B: Engineering, 2016
- Mechanical energy profiles of the combined ankle–foot system in normal gait: Insights for prosthetic designsGait & Posture, 2013
- Comparative roll-over analysis of prosthetic feetJournal of Biomechanics, 2009
- The Effects of Prosthetic Foot Roll-Over Shape Arc Length on the Gait of Trans-Tibial Prosthesis UsersProsthetics and Orthotics International, 2006
- Ageing effects on knee and ankle joint angles at key events and phases of the gait cycleJournal of Medical Engineering & Technology, 2006
- The condition for dynamic stabilityJournal of Biomechanics, 2005
- Roll-over shapes of human locomotor systems: effects of walking speedClinical Biomechanics, 2004
- Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputeesGait & Posture, 2003
- The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's ability to ambulateArchives of Physical Medicine and Rehabilitation, 2002