Cardiovascular magnetic resonance imaging and transthoracic echocardiography in the assessment of stenotic aortic valve area: a comparative study
Authors:
- 1 November 2012
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (9) , 995-1003
Abstract
Background: Magnetic resonance (MR) imaging and echocardiography both allow assessment of aortic valve stenosis. In MR the aortic valve area (AvA) is measured using planimetry while in transthoracic echocardiography (TTE) AvA is usually calculated by applying the continuity equation. Purpose: To compare the measured stenotic aortic valve areas using five different MR-acquisition alternatives with the corresponding area values calculated by TTE. Material and Methods: The aortic valve was imaged in 14 patients, with diagnosed aortic valve stenosis, using balanced steady state free precession (bSSFP) gradient echo (GE) and phase contrast imaging (PC). Three adjacent slices were planned to encompass the aortic valve and the aortic valve area was measured using planimetry. The two sets of complex valued images generated by the PC sequence formed three kinds of images that could be used for aortic valve area measurements: the magnitude image (PC/Mag), the modulus (PCA/M), and phase difference (PCA/P) between the two complex images, respectively. The valve area from TTE was calculated using the continuity equation. A cut-off of2 was used as a criteria for severe stenosis. Results: The mean area differences between the different MR acquisitions and TTE method were −0.05±0.37 cm2 (GE), −0.18±0.46 cm2 (bSSFP), 0.27-0.43 cm2 (PC/Mag), 0.15±0.32 cm2 (PCA/P), and 0.26±0.27 cm2 (PCA/M). The valve area was significantly overestimated using PCA/M that, in turn, implied a significant underestimation of the aortic valve stenosis severity compared to the assessments using TTE. Conclusion: The smallest area valve difference between TTE and an MR-acquisition alternative is obtained with gradient echo images. The use of PCA/M leads to significant differences in planimetry measurements of the aortic valve orifice and the gradation of the stenosis severity compared to TTE.Keywords
This publication has 24 references indexed in Scilit:
- Planimetric and continuity equation assessment of aortic valve area: Head to head comparison between cardiac magnetic resonance and echocardiographyJournal of Magnetic Resonance Imaging, 2007
- Absolute assessment of aortic valve stenosis by planimetry using cardiovascular magnetic resonance imaging: Comparison with transœsophageal echocardiography, transthoracic echocardiography, and cardiac catheterisationEuropean Journal of Radiology, 2006
- Planimetry of Aortic Valve Area in Aortic Stenosis by Magnetic Resonance ImagingInvestigative Radiology, 2005
- Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniquesHeart, 2004
- Quantification of valvular aortic stenosis by magnetic resonance imagingAmerican Heart Journal, 2002
- Breath-hold FLASH and FISP Cardiovascular MR Imaging: Left Ventricular Volume Differences and ReproducibilityRadiology, 2002
- Planimetry of orifice area in aortic stenosis using multiplane transesophageal ecocardiographyJACC, 1993
- Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiographyJournal of Magnetic Resonance Imaging, 1991
- Two-dimensional transesophageal echocardiographic determination of aortic valve area in adults with aortic stenosisAmerican Heart Journal, 1991
- Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography.Circulation, 1985