Dynamic transitions for fast joint acquisition and reconstruction of CEST-Rex and T1
Preprint
Abstract
Purpose: This work proposes a method for the simultaneous estimation of the exchange-dependent relaxation rate Rex and the longitudinal relaxation time T1 from a single acquisition. Methods: A novel acquisition scheme was developed that combines CEST saturation with an inversion pulse and a Look-Locker readout to capture the magnetization evolution starting from the inverse transient Z-spectrum. The corresponding signal model, derived from the Bloch-McConnell equations, describes both the transient Z-spectrum and the Look-Locker dynamics. A model-based reconstruction approach is employed to jointly estimate Rex and T1. The proposed method was validated using a numerical phantom and benchmarked against conventional CEST and Look-Locker T1 mapping in phantom and in vivo on a clinical 3T scanner. Results: The joint estimation approach demonstrated strong agreement with ground truth and conventional methods across a wide range of T1 and CEST parameters. The acquisition time was reduced by 20-30% compared to standard CEST protocols, while providing higher signal-to-noise ratio (SNR) in parameter maps. Conclusion: The proposed technique enables robust and efficient simultaneous quantification of CEST Rex and T1 in a single acquisition. It improves parameter map quality and reduces scan time, making it suitable for both phantom and in vivo imaging across a wide range of physiological conditions.Keywords
All Related Versions
This publication has 52 references indexed in Scilit:
- Amide Proton Transfer‐Weighted MRI, Associations with Clinical Severity and Prognosis in Ischemic StrokesJournal of Magnetic Resonance Imaging, 2024
- Clinical applications of chemical exchange saturation transfer (CEST) MRIJournal of Magnetic Resonance Imaging, 2017
- Model-based reconstruction for T1 mapping using single-shot inversion-recovery radial FLASHInternational Journal of Imaging Systems and Technology, 2016
- Simultaneous mapping of water shift and B1(WASABI)—Application to field‐Inhomogeneity correction of CESTMRI dataMagnetic Resonance in Medicine, 2016
- A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imagingContrast Media & Molecular Imaging, 2015
- Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparationMagnetic Resonance in Medicine, 2012
- Model‐based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin‐echo MRIJournal of Magnetic Resonance Imaging, 2011
- Second order total generalized variation (TGV) for MRIMagnetic Resonance in Medicine, 2010
- Array compression for MRI with large coil arraysMagnetic Resonance in Medicine, 2007
- Fast high‐resolution T1 mapping of the human brainMagnetic Resonance in Medicine, 2005