Utility of the Loop-Mediated Isothermal Amplification Assay for the Diagnosis of Visceral Leishmaniasis from Blood Samples in Ethiopia
Open Access
- 26 July 2021
- journal article
- research article
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 105 (4) , 1050-1055
Abstract
: Rapid and accurate diagnosis of visceral leishmaniasis (VL) is needed to initiate prompt treatment to reduce morbidity and mortality. Here, we evaluated the performance of loop-mediated isothermal amplification (LAMP) assay for the diagnosis of VL from blood in an endemic area in Ethiopia. LAMP was positive in 117/122 confirmed VL cases and negative in 149/152 controls, resulting in a sensitivity of 95.9% (95% CI: 90.69–98.66) and a specificity of 98.0% (95% CI: 94.34–99.59), respectively. The sensitivity of the LAMP assay was 95.0% (95% CI: 88.61–98.34) in HIV-negatives and 100% (95% CI: 85.18–100.0) in HIV-positives. Compared with microscopy, LAMP detected 82/87 (94.3%, 95% CI: 87.10–98.11) of the microscopy+ cases and was negative in 11/27 (40.7%, 95% CI: 22.39–61.20) of the microscopy− cases. Compared with the rK39 serology, LAMP detected 113/120 (94.2%, 95% CI: 88.35–97.62) of the rK39+ cases and was negative in 149/154 (96.8%, 95% CI: 92.59–98.94) of the rK39− cases. However, when compared with microscopy only, rK39 detected 83/87 (95.4%, 95% CI: 88.64–98.73) of the microscopy+ cases and negative in only 12/27 (44.4%, 95% CI: 25.48–64.67) of the microscopy– cases. There was an excellent agreement between rK39 and LAMP (Kappa = 0.91, 95% CI: 0.86–0.96). Furthermore, an algorithm using rK39 followed by LAMP would yield a sensitivity of 99.2% (95%CI: 95.52–99.89) and a specificity of 98.0% (95% CI: 94.34–99.59). The findings demonstrate that LAMP assay is an accurate and rapid molecular assay for VL diagnosis, including in HIV-1 coinfected patients, in an endemic setting.Keywords
This publication has 44 references indexed in Scilit:
- Diagnostic accuracy of loop-mediated isothermal amplification (LAMP) for detection of Leishmania DNA in buffy coat from visceral leishmaniasis patientsParasites & Vectors, 2012
- The burden of neglected tropical diseases in Ethiopia, and opportunities for integrated control and eliminationParasites & Vectors, 2012
- Persistence of Leishmania donovani Antibodies in Past Visceral Leishmaniasis Cases in IndiaClinical and Vaccine Immunology, 2011
- Development of a Reverse Transcriptase Loop-Mediated Isothermal Amplification (LAMP) Assay for the Sensitive Detection of Leishmania Parasites in Clinical SamplesThe American Journal of Tropical Medicine and Hygiene, 2010
- Sensitive, Specific, and Rapid Detection of Leishmania donovani DNA by Loop-Mediated Isothermal AmplificationThe American Journal of Tropical Medicine and Hygiene, 2009
- The Relationship between Leishmaniasis and AIDS: the Second 10 YearsClinical Microbiology Reviews, 2008
- Loop-Mediated Isothermal Amplification (LAMP) Method for Rapid Detection of Trypanosoma brucei rhodesiensePLOS Neglected Tropical Diseases, 2008
- Comparison between Quantitative Nucleic Acid Sequence-Based Amplification, Real-Time Reverse Transcriptase PCR, and Real-Time PCR for Quantification ofLeishmaniaParasitesJournal of Clinical Microbiology, 2008
- Detection of Four Plasmodium Species by Genus- and Species-Specific Loop-Mediated Isothermal Amplification for Clinical DiagnosisJournal of Clinical Microbiology, 2007
- Molecular Diagnosis of Leishmaniasis: Current Status and Future ApplicationsJournal of Clinical Microbiology, 2007