Transient in-stent stenosis at mid-term angiographic follow-up in patients treated with SILK flow diverter stents: incidence, clinical significance and long-term follow-up
- 7 September 2018
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 11 (2) , 166-170
Abstract
Background Little is known about in-stent stenosis (ISS) in patients with aneurysms treated with flow diverter (FD) stents. The reported incidence in the literature varies significantly. Objective The aim of this study was to assess the incidence, severity, distribution, clinical significance, and possible predictors for ISS. Methods Between July 2012 and June 2016 we retrospectively reviewed all patients treated with SILK FDs in our center. Only cases with short-term (4±2 months) and long-term (>1 year) follow-ups with digital subtraction angiograms were included. ISS was graded as mild (50%). The following predictors for ISS were assessed: gender, age, the presence of subarachnoid hemorrhage, aneurysm size, location, occlusion status, and post-stenting angioplasty. Results Thirty-six patients met the inclusion criteria. At mid-term follow-up, ISS was observed in 16/36 patients (44%). Eleven patients (69%) had mild ISS, three (19%) moderate, and two (12%) severe ISS. ISS was diffuse in 11 patients (69%) and focal in five patients (31%). All patients were asymptomatic. Thirteen patients were maintained on dual antiplatelet therapy and three on aspirin alone. At long-term follow-up, complete ISS resolution was seen in 11 patients, improvement in three and worsening in two patients. No de novo ISS occurrence was observed. On univariate analysis there was no significant predictor for ISS. Conclusions Transient ISS after FD deployment is a common asymptomatic finding on mid-term angiographic follow-up. Complete resolution or improvement at long-term follow-up is seen in most patients who are maintained on dual antiplatelet therapy.Keywords
This publication has 30 references indexed in Scilit:
- Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical TrialRadiology, 2013
- New Generation of Flow Diverter (Surpass) for Unruptured Intracranial AneurysmsStroke, 2013
- Biological responses in stented arteriesCardiovascular Research, 2013
- Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter StudyAmerican Journal of Neuroradiology, 2012
- Long-Term Follow-Up after Treatment of Intracranial Aneurysms with the Pipeline Embolization Device: Results from a Single CenterAmerican Journal of Neuroradiology, 2011
- Immediate and Midterm Results following Treatment of Recently Ruptured Intracranial Aneurysms with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2011
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICENeurosurgery, 2009
- In stent restenosis: bane of the stent eraJournal of Clinical Pathology, 2006
- Balloon angioplasty. Natural history of the pathophysiological response to injury in a pig model.Circulation Research, 1985