Relay-type sensing mode: A strategy to push the limit on nanomechanical sensor sensitivity based on the magneto lever
- 14 November 2022
- journal article
- research article
- Published by Tsinghua University Press in Nano Research
- Vol. 16 (2) , 3231-3239
Abstract
Ultrasensitive molecular detection and quantization are crucial for many applications including clinical diagnostics, functional proteomics, and drug discovery; however, conventional biochemical sensors cannot satisfy the stringent requirements, and this has resulted in a long-standing dilemma regarding sensitivity improvement. To this end, we have developed an ultrasensitive relay-type nanomechanical sensor based on a magneto lever. By establishing the link between very weak molecular interaction and five orders of magnitude larger magnetic force, analytes at ultratrace level can produce a clearly observable mechanical response. Initially, proof-of-concept studies showed an improved detection limit up to five orders of magnitude when employing the magneto lever, as compared with direct detection using probe alone. In this study, we subsequently demonstrated that the relay-type sensing mode was universal in application ranging from micromolecule to macromolecule detection, which can be easily extended to detect enzymes, DNA, proteins, cells, viruses, bacteria, chemicals, etc. Importantly, we found that, sensitivity was no longer subject to probe affinity when the magneto lever was sufficiently high, theoretically, even reaching single-molecule resolution.Keywords
This publication has 57 references indexed in Scilit:
- Detecting protein adsorption and binding using magnetic nanoparticle probesSensors and Actuators B: Chemical, 2011
- Interactions of single-stranded DNA on microcantileversCurrent Opinion in Colloid & Interface Science, 2011
- Cantilever Array Sensors Detect Specific Carbohydrate−Protein Interactions with Picomolar SensitivityACS Nano, 2011
- Reduction of Elevated Plasma Osteopontin Levels With Resection of Non–Small-Cell Lung CancerJournal of Clinical Oncology, 2010
- Redox Actuation of a Microcantilever Driven by a Self-Assembled Ferrocenylundecanethiolate Monolayer: An Investigation of the Origin of the Micromechanical Motion and Surface StressJournal of the American Chemical Society, 2009
- Highly specific label-free protein detection from lysed cells using internally referenced microcantilever sensorsBiosensors and Bioelectronics, 2008
- Magneto-Mechanical Detection of Nucleic Acids and Telomerase Activity in Cancer CellsJournal of the American Chemical Society, 2004
- London‐V. D. waals forces in colloidal systemsRecueil des Travaux Chimiques des Pays-Bas, 1938
- The London—van der Waals attraction between spherical particlesPhysica, 1937
- The general theory of molecular forcesTransactions of the Faraday Society, 1937