Estimation of Potential Distribution during Crevice Corrosion through Analysis of I–V Curves Obtained by LAPS
Open Access
Abstract
Crevice corrosion is a type of local corrosion which occurs when a metal surface is confined in a narrow gap on the order of 10 μm filled with a solution. Because of the inaccessible geometry, experimental methods to analyze the inner space of the crevice have been limited. In this study, a light-addressable potentiometric sensor (LAPS) was employed to estimate the potential distribution inside the crevice owing to the IR drop by the anodic current flowing out of the structure. Before crevice corrosion, the I–V curve of the LAPS showed a potential shift, depending on the distance from the perimeter. The shift reflected the potential distribution due to the IR drop by the anodic current flowing out of the crevice. After crevice corrosion, the corrosion current increased exponentially, and a local pH change was detected where the corrosion was initiated. A simple model of the IR drop was used to calculate the crevice gap, which was 12 μm—a value close to the previously reported values. Thus, the simultaneous measurement of the I–V curves obtained using a LAPS during potentiostatic electrolysis could be applied as a new method for estimating the potential distribution in the crevice.Keywords
This publication has 15 references indexed in Scilit:
- Simultaneous visualization of pH and Cl− distributions inside the crevice of stainless steelCorrosion Science, 2016
- The Numerical Analysis of Potential / Current Density Distribution in Crevice Corrosion Propagation StageCorrosion Engineering, 2016
- Propagation Analysis of Crevice Corrosion on SUS304 Stainless Steel Under Potentiostatic Condition in Artificial Sea WaterCorrosion Engineering, 2015
- The Effect of Potential and Temperature on Crevice Corrosion Incubation Time for Stainless Steels in Diluted Chloride Ion EnvironmentCorrosion Engineering, 2009
- Scanning-laser-beam semiconductor pH-imaging sensorSensors and Actuators B: Chemical, 1994
- Light-Addressable Potentiometric Sensor for Biochemical SystemsScience, 1988
- Test techniques for pitting and crevice corrosion resistance of stainless steels and nickel-base alloys in chloride-containing environmentsInternational Materials Reviews, 1987
- Localized Corrosion of Stainless Steels Part 1 Pitting and Crevice CorrosionTetsu-to-Hagane, 1977
- Critical Potential for Growth of Localized Corrosion of Stainless Steel in Chloride MediaCorrosion, 1972
- On the mechanism of crevice corrosion of stainless Cr steelsCorrosion Science, 1971