An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
- T AkutsuTAT Akutsu
- M AndoMAM Ando
- K AraiKAK Arai
- Y AraiYAY Arai
- S ArakiSAS Araki
- A ArayaAAA Araya
- N AritomiNAN Aritomi
- Y AsoYAY Aso
- S BaeSBS Bae
- Y BaeYBY Bae
- L BaiottiLBL Baiotti
- R BajpaiRBR Bajpai
- 13 January 2020
- journal article
- research article
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 37 (3) , 035004
Abstract
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS. We also demonstrated that the root mean square of residual noise was measured to be 8.2 Hz in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.Keywords
Funding Information
- Ministry of Education, Culture, Sports, Science and Technology (24103005)
- Japan Society for the Promotion of Science (26000005, Core-to-Core Program, Leading-edge Research Infrastructur)
- National Research Foundation of Korea
This publication has 34 references indexed in Scilit:
- Interferometer design of the KAGRA gravitational wave detectorPhysical Review D, 2013
- A new bound on excess frequency noise in second harmonic generation in PPKTP at the 10^−19 levelOptics Express, 2012
- Sensitivity studies for third-generation gravitational wave observatoriesClassical and Quantum Gravity, 2011
- The variable finesse locking techniqueClassical and Quantum Gravity, 2006
- Delivery of high-stability optical and microwave frequency standards over an optical fiber networkJournal of the Optical Society of America B, 2003
- Dynamic resonance of light in Fabry–Perot cavitiesPhysics Letters A, 2002
- New signal extraction scheme with harmonic demodulation for power-recycled Fabry–Perot–Michelson interferometersPhysics Letters A, 2000
- Demonstration of a power-recycled Michelson interferometer with Fabry–Perot arms by frontal modulationOptics Letters, 1995
- Recycling in laser-interferometric gravitational-wave detectorsPhysical Review D, 1988
- Laser phase and frequency stabilization using an optical resonatorApplied Physics B, 1983