Haptic Feedback and Dynamic Active Constraints for Robot-Assisted Endovascular Catheterization
- 1 October 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1770-1775
Abstract
Robotic and computer assistance can bring significant benefits to endovascular procedures in terms of precision and stability, reduced radiation doses, improved comfort and access to difficult and tortuous anatomy. However, the design of current commercially available platforms tends to alter the natural bedside manipulation skills of the operator, so that the manually acquired experience and dexterity are not well utilized. Furthermore, most of these systems lack of haptic feedback, preventing their acceptance and limiting the clinical usability. In this paper a new robotic platform for endovascular catheterization, the CathBot, is presented. It is an ergonomic master-slave system with navigation system and integrated vision-based haptic feedback, designed to maintain the natural bedside skills of the vascular surgeon. Unlike previous work reported in literature, dynamic motion tracking of both the vessel walls the catheter tip is incorporated to create dynamic active constraints. The system was evaluated through a combined quantitative and qualitative user study simulating catheterization tasks on a phantom. Forces exerted on the phantom were measured. The results showed a 70% decrease in mean force and 61% decrease in maximum force when force feedback is provided. This research provides the first integration of vision-based dynamic active constraints within an ergonomic robotic catheter manipulator. The technological advances presented here, demonstrates that vision-based haptic feedback can improve the effectiveness, precision, and safety of robot-assisted endovascular procedures.Keywords
This publication has 14 references indexed in Scilit:
- Optimal Viewing Angle Determination for Multiple Vessel Segments in Coronary Angiographic ImageIEEE Transactions on Nuclear Science, 2014
- Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A ReviewAnnals of Biomedical Engineering, 2013
- Motion-adapted catheter navigation with real-time instantiation and improved visualisationJournal of Robotic Surgery, 2013
- Robot-assisted Fenestrated Endovascular Aneurysm Repair (FEVAR) Using the Magellan SystemJournal of Vascular and Interventional Radiology, 2013
- A force feedback system for endovascular catheterisation2012
- Haptic Virtual Fixture for Robotic Cardiac Catheter NavigationArtificial Organs, 2011
- Development of a Force‐Reflecting Robotic Platform for Cardiac Catheter NavigationArtificial Organs, 2010
- Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devicesThe International Journal of Medical Robotics and Computer Assisted Surgery, 2010
- Ablation of Atrial Fibrillation Utilizing Robotic Catheter Navigation in Comparison to Manual Navigation and Ablation: Single‐Center ExperienceJournal of Cardiovascular Electrophysiology, 2009
- A meta-analysis of 21 178 patients undergoing open or endovascular repair of abdominal aortic aneurysmBritish Journal of Surgery, 2008