Correlations between heart sound components and hemodynamic variables
Authors:
Open Access
- 13 April 2024
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-15
Abstract
Although the esophageal stethoscope is used for continuous auscultation during general anesthesia, few studies have investigated phonocardiographic data as a continuous hemodynamic index. In this study, we aimed to induce hemodynamic variations and clarify the relationship between the heart sounds and hemodynamic variables through an experimental animal study. Changes in the cardiac contractility and vascular resistance were induced in anesthetized pigs by administering dobutamine, esmolol, phenylephrine, and nicardipine. In addition, a decrease in cardiac output was induced by restricting the venous return by clamping the inferior vena cava (IVC). The relationship between the hemodynamic changes and changes in the heart sound indices was analyzed. Experimental data from eight pigs were analyzed. The mean values of the correlation coefficients of changes in S1 amplitude (ΔS1amp) with systolic blood pressure (ΔSBP), pulse pressure (ΔPP), and ΔdP/dt during dobutamine administration were 0.94, 0.96, and 0.96, respectively. The mean values of the correlation coefficients of ΔS1amp with ΔSBP, ΔPP, and ΔdP/dt during esmolol administration were 0.80, 0.82, and 0.86, respectively. The hemodynamic changes caused by the administration of phenylephrine and nicardipine did not correlate significantly with changes in the heart rate. The S1 amplitude of the heart sound was significantly correlated with the hemodynamic changes caused by the changes in cardiac contractility but not with the variations in the vascular resistance. Heart sounds can potentially provide a non-invasive monitoring method to differentiate the cause of hemodynamic variations.Keywords
Funding Information
- Korea Health Industry Development Institute (HR20C0026)
- Asan Institute for Life Sciences, Asan Medical Center (2022IP0053)
This publication has 28 references indexed in Scilit:
- Anatomical Differences Between Human and Pig Hearts and Their Relevance for Cardiac Xenotransplantation Surgical TechniqueJACC: Case Reports, 2022
- Partial clamping of the infrahepatic inferior vena cava for blood loss reduction during anatomic liver resection: A prospective, randomized, controlled trialSurgery, 2017
- Sex bias exists in basic science and translational surgical researchSurgery, 2014
- Heart sounds analysis via esophageal stethoscope system in beaglesJournal of Clinical Monitoring and Computing, 2013
- Computer aided analysis of phonocardiogramJournal of Medical Engineering & Technology, 2007
- Bleeding during hepatectomy can be reduced by clamping the inferior vena cava below the liverSurgery, 2004
- The use of the Hilbert transform in ECG signal analysisComputers in Biology and Medicine, 2001
- Anatomy of the pig heart: comparisons with normal human cardiac structureJournal of Anatomy, 1998
- Heart sound propagation in the human thoraxClinical Physics and Physiological Measurement, 1985
- Current Concepts of the Genesis of Heart Sounds1978