A phase processor used in terahertz interferometer for tokamak
Authors:
- 1 June 2022
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (06) , P06036
Abstract
The commonly used phase processing techniques include coherence method, zero-crossing comparison method and FFT method. Due to the influence of noise, amplitude modulation and frequency modulation, these phase processing methods are easy to cause errors, thus affecting the measurement accuracy. In this paper, a phase processor based on all-phase fast Fourier transform is developed. The principle of the phase processing algorithm is analyzed, and the implementation process of the algorithm on FPGA is described. The effectiveness of the method is tested under different conditions. The experimental results show that the standard deviation of phase processing is 0.387° when the signal is sampled simultaneously under 90% AM modulation. When asynchronous sampling and 50% FM, the phase processing error is 0.371°. This phase processer has been used to the terahertz interferometer of the HL-2M device, the phase change of the output signal of the interferometer can be accurately processed when the plasma density changes dramatically, and the loss of phase processing information can be effectively avoided in the plasma diagnosis process. Based on the technical research proposed in this paper, a more accurate phase processing reference scheme is provided for plasma diagnosis of interferometer.Keywords
This publication has 24 references indexed in Scilit:
- A precision control method for plasma electron density and Faraday rotation angle measurement on HL-2APlasma Science and Technology, 2017
- Initial measurements of plasma current and electron density profiles using a polarimeter/interferometer (POINT) for long pulse operation in EAST (invited)Review of Scientific Instruments, 2016
- Operation results of the KSTAR far infrared interferometerReview of Scientific Instruments, 2016
- Multichannel Microwave Interferometer for Simultaneous Measurement of Electron Density and its Fluctuation on HL-2A TokamakPlasma Science and Technology, 2016
- Real-Time Dynamic Spectrum Analysis for Plasma Electron Density and Faraday Rotation Angle Measurement on HL-2APlasma Science and Technology, 2015
- The component development status of HL-2M tokamakFusion Engineering and Design, 2015
- Plasma density control in real-time on the COMPASS tokamakFusion Engineering and Design, 2015
- Fringe-jump corrected far infrared tangential interferometer/polarimeter for a real-time density feedback control system of NSTX plasmasReview of Scientific Instruments, 2010
- Phase detection using AD8302 evaluation board in the superheterodyne microwave interferometer for line average plasma electron density measurementsMeasurement, 2007
- Principles of Plasma Diagnostics: Second EditionPlasma Physics and Controlled Fusion, 2002