Dual-Energy Parathyroid 4D-CT: Improved Discrimination of Parathyroid Lesions from Thyroid Tissue Using Noncontrast 40-keV Virtual Monoenergetic Images
- 2 September 2021
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (11) , 2001-2008
Abstract
BACKGROUND AND PURPOSE: In parathyroid CT, a noncontrast phase aids discrimination of parathyroid lesions (not iodine-containing) from thyroid tissue (iodine-containing). When thyroid iodine is pathologically diminished, this differentiation is difficult with standard CT. Because the attenuation of an element is maximal near its K-edge (iodine = 33.2 keV), we hypothesized that dual-energy CT 40-keV virtual monoenergetic images will accentuate thyroid iodine relative to standard images, improving the differentiation of thyroid from parathyroid lesions. Our purpose was to test this hypothesis through quantitative assessment of Hounsfield unit attenuation and contrast-to-noise on dual-energy CT standard (70-keV) and 40-keV noncontrast images. MATERIALS AND METHODS: For this retrospective study including 20 dual-energy parathyroid CTs, we used an ROI-based analysis to assess the attenuation of thyroid tissue, parathyroid lesions, and sternocleidomastoid muscle as well as corresponding contrast-to-noise on standard and 40- keV noncontrast images. Wilcoxon signed rank tests were performed to compare differences between 70 and 40 keV. RESULTS: Absolute and percentage increases in attenuation at 40 keV were significantly greater for thyroid gland than for parathyroid lesions and sternocleidomastoid muscle (P < .001 for all). Significant increases in the contrast-to-noise of thyroid relative to parathyroid lesions (median increase, 0.8; P < .001) and relative to sternocleidomastoid muscle (median increase, 1.3; P < .001) were observed at 40 keV relative to 70 keV. CONCLUSIONS: Forty-kiloelectron volt virtual monoenergetic images facilitate discrimination of parathyroid lesions from thyroid tissue by significantly increasing thyroid attenuation and associated contrast-to-noise. These findings are particularly relevant for parathyroid lesions that exhibit isoattenuation to the thyroid on parathyroid CT arterial and venous phases and could, therefore, be missed without the noncontrast phase.Keywords
This publication has 29 references indexed in Scilit:
- Imaging of the parathyroid glands in primary hyperparathyroidismEuropean Journal of Endocrinology, 2016
- Parathyroid Adenomas and Hyperplasia on Four-dimensional CT Scans: Three Patterns of Enhancement Relative to the Thyroid Gland Justify a Three-Phase ProtocolRadiology, 2015
- Optimal Virtual Monochromatic Images for Evaluation of Normal Tissues and Head and Neck Cancer Using Dual-Energy CTAmerican Journal of Neuroradiology, 2015
- Papillary Thyroid Cancer: Dual-Energy Spectral CT Quantitative Parameters for Preoperative Diagnosis of Metastasis to the Cervical Lymph NodesRadiology, 2015
- 3-phase dual-energy CT scan as a feasible salvage imaging modality for the identification of non-localizing parathyroid adenomas: A prospective studyJournal of Otolaryngology - Head & Neck Surgery, 2015
- Dynamic CT for Parathyroid Disease: Are Multiple Phases Necessary?American Journal of Neuroradiology, 2014
- Comparison of dual-energy CT-derived iodine content and iodine overlay of normal, inflammatory and metastatic squamous cell carcinoma cervical lymph nodesEuropean Radiology, 2013
- Dual-Energy CT Applications in Head and Neck ImagingAmerican Journal of Roentgenology, 2012
- Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CTRadiology, 2011
- Is Preoperative Investigation of the Thyroid Justified in Patients Undergoing Parathyroidectomy for Hyperparathyroidism?Thyroid®, 2002